Assessment of membrane‐based downstream purification processes as a replacement to traditional resin bead for monoclonal antibody purification

Membrane chromatography devices are a viable alternative to packed-bed resins and enable highly productive purification cascades for monoclonal antibodies and Fc-fusion proteins. In this study, ion exchange and protein A membrane chromatography performances were assessed and compared with their resin counterparts. Protein A dynamic binding capacities were higher than 50 g/L for two of the tested membranes and with a residence time of 0.2 min. For polishing, it was observed that aggregate clearance was generally less performant with membrane separation when compared to resins with similar ligands. However, the comparable yield and increased productivity of membranes could be enough to consider their implementation. In addition, lifetime studies demonstrated that the performance of membranes remained robust over cycles. One hundred cycles were reached for most of the tested membranes with no impact on the process performance nor product quality. Finally, purification cascades were fully operated with membranes, from capture to polishing, reaching good levels of host cells proteins (less than 50 ppm) and aggregates (equal to or less than 1%). The outcome of this study demonstrated that resin chromatography could be fully replaced by membranes for monoclonal antibody and Fc-fusion protein purification processes.

Authors

Institutions

Publication Details

Journal
Biotechnology Progress
Published
2024-09-16
DOI
https://doi.org/10.1002/btpr.3508
Citations
3
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of membrane‐based downstream purification processes as a replacement to traditional resin bead for monoclonal antibody purification

Jean‐Marc Bielser, Arnaud Périlleux, Kevin Botelho Ferreira, Jonathan Souquet et al.
3 citations
Biotechnology Progress
Protein purification and stability
0.70
article

Assessment of membrane‐based downstream purification processes as a replacement to traditional resin bead for monoclonal antibody purification

Jean‐Marc Bielser, Arnaud Périlleux, Kevin Botelho Ferreira, Jonathan Souquet, Victor Pasquier, Morgane Lergenmuller, Alexis Tottoli
article en
3 citations

Abstract

Membrane chromatography devices are a viable alternative to packed-bed resins and enable highly productive purification cascades for monoclonal antibodies and Fc-fusion proteins. In this study, ion exchange and protein A membrane chromatography performances were assessed and compared with their resin counterparts. Protein A dynamic binding capacities were higher than 50 g/L for two of the tested membranes and with a residence time of 0.2 min. For polishing, it was observed that aggregate clearance was generally less performant with membrane separation when compared to resins with similar ligands. However, the comparable yield and increased productivity of membranes could be enough to consider their implementation. In addition, lifetime studies demonstrated that the performance of membranes remained robust over cycles. One hundred cycles were reached for most of the tested membranes with no impact on the process performance nor product quality. Finally, purification cascades were fully operated with membranes, from capture to polishing, reaching good levels of host cells proteins (less than 50 ppm) and aggregates (equal to or less than 1%). The outcome of this study demonstrated that resin chromatography could be fully replaced by membranes for monoclonal antibody and Fc-fusion protein purification processes.

Biotechnology ProgressVol. 41(1)
Merck Serono S.A. (Switzerland) (CH)
Openalex Percentile: Top 30%
Protein purification and stability
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of membrane‐based downstream purification processes as a replacement to traditional resin bead for monoclonal antibody purification — Jean‐Marc Bielser, Arnaud Périlleux, et al. · Biotechnology Progress (2024) | TGRS Research Map | TGRS