Output Voltage Ripple Suppression of High Voltage Power Supply for Ionising Radiation Detection Units
Operation and results of tests of operating model of high-voltage power supply of ionizing radiation detection units with active suppression of output voltage pulsations are described. The joint effect of the smoothing RC-filter and the circuit of active pulsation suppression on the value of their amplitude was experimentally investigated. The device was tested at an output voltage of 1 kV and a load current of 1 mA. The minimum peak-to-peak ripple amplitude achieved does not exceed 1mV.
Authors
- A. S. Sergeev (ORCID: https://orcid.org/0000-0002-7709-9542)
Institutions
- Ural Federal University (RU)
Publication Details
- Journal
- ANRI
- Published
- 2024-09-13
- DOI
- https://doi.org/10.37414/2075-1338-2024-118-3-55-60
- Primary Topic
- Radiation Effects in Electronics
- Type
- article
- Field-Weighted Citation Impact
- 0.00