Clot in the Blood Bag: A Case Report

Clot formation within a blood bag is a rare but significant issue, posing risks to the safety and quality of transfused blood products. We report the root cause analysis of a large clot found in a blood bag during routine component preparation. The analysis identified three potential contributing factors: improper vein selection leading to low flow rates, delays in tube stripping, and the use of a faulty blood collection monitor. These factors together facilitated the activation of coagulation, resulting in clot formation. To address these issues, corrective actions were implemented, including enhanced staff training on vein selection and phlebotomy techniques, timely and proper tube stripping procedures, and the replacement of faulty blood collection monitors with regularly calibrated equipment. Additionally, standard operating procedures (SOPs) were updated to incorporate these corrective measures. The implementation of these actions aims to prevent the recurrence of such incidents, ensuring the integrity of blood products and the safety of transfusion practices. This case highlights the importance of continuous monitoring and adherence to established protocols in blood collection and processing.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-09-15
DOI
https://doi.org/10.7759/cureus.69452
Citations
1
Primary Topic
Case Reports on Hematomas
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clot in the Blood Bag: A Case Report

Arthi Rajkumar, Soundharya Vetriveeran, Suresh Kumar Iyyapan, Hari Haran Annadurai et al.
1 citations
Cureus
Case Reports on Hematomas
0.57
article

Clot in the Blood Bag: A Case Report

Arthi Rajkumar, Soundharya Vetriveeran, Suresh Kumar Iyyapan, Hari Haran Annadurai, Sahayaraj James
article en
1 citations

Abstract

Clot formation within a blood bag is a rare but significant issue, posing risks to the safety and quality of transfused blood products. We report the root cause analysis of a large clot found in a blood bag during routine component preparation. The analysis identified three potential contributing factors: improper vein selection leading to low flow rates, delays in tube stripping, and the use of a faulty blood collection monitor. These factors together facilitated the activation of coagulation, resulting in clot formation. To address these issues, corrective actions were implemented, including enhanced staff training on vein selection and phlebotomy techniques, timely and proper tube stripping procedures, and the replacement of faulty blood collection monitors with regularly calibrated equipment. Additionally, standard operating procedures (SOPs) were updated to incorporate these corrective measures. The implementation of these actions aims to prevent the recurrence of such incidents, ensuring the integrity of blood products and the safety of transfusion practices. This case highlights the importance of continuous monitoring and adherence to established protocols in blood collection and processing.

CureusVol. 16(9)
Saveetha University (IN)
Openalex Percentile: Top 30%
Case Reports on Hematomas
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.