Numerical study using the finite volume method on the thermal and energy performance of a regulated underfloor heating system incorporating PCM in a ventilated room

• Analyzing the viability of integrating PCM in a ventilated room with a controlled heating floor system. • Using PCM in the heating floor can result in significant energy savings. • It is possible to implement the suggested system to move the electrical demand from peak to non-peak times. A physical model is performed to assess the thermal and energetic advantages of using PCM in controlling and regulating the indoor temperature of a ventilated room with an underfloor heating system incorporating a PCM. The heating source is regulated to keep the cavity air temperature in a small interval assuring a certain level of comfort without wasting too much energy. By contrasting our numerical results with numerical data from the literature, the suggested model was validated. Physical processes are solved numerically using computational fluid dynamics by a detailed 2D transient simulation integrating real climatic data of Agadir, Tangier and Casablanca. The simulations carried out justified the suitability of using the PCM with Agadir and Casablanca climate types by a saving of heating power reaching 18.80 % and 17.33 %, respectively.

Authors

Publication Details

Journal
Scientific African
Published
2024-09-15
DOI
https://doi.org/10.1016/j.sciaf.2024.e02363
Citations
2
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study using the finite volume method on the thermal and energy performance of a regulated underfloor heating system incorporating PCM in a ventilated room

T. El Rhafiki, Y. Khattari, El Hassan Sebbar, Y. Chaibi
2 citations
Scientific African
Phase Change Materials Research
0.43
article

Numerical study using the finite volume method on the thermal and energy performance of a regulated underfloor heating system incorporating PCM in a ventilated room

T. El Rhafiki, Y. Khattari, El Hassan Sebbar, Y. Chaibi
article en
2 citations

Abstract

• Analyzing the viability of integrating PCM in a ventilated room with a controlled heating floor system. • Using PCM in the heating floor can result in significant energy savings. • It is possible to implement the suggested system to move the electrical demand from peak to non-peak times. A physical model is performed to assess the thermal and energetic advantages of using PCM in controlling and regulating the indoor temperature of a ventilated room with an underfloor heating system incorporating a PCM. The heating source is regulated to keep the cavity air temperature in a small interval assuring a certain level of comfort without wasting too much energy. By contrasting our numerical results with numerical data from the literature, the suggested model was validated. Physical processes are solved numerically using computational fluid dynamics by a detailed 2D transient simulation integrating real climatic data of Agadir, Tangier and Casablanca. The simulations carried out justified the suitability of using the PCM with Agadir and Casablanca climate types by a saving of heating power reaching 18.80 % and 17.33 %, respectively.

Scientific AfricanVol. 26
Affordable and clean energy
Openalex Percentile: Top 42%
Phase Change Materials Research
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.