Determination of sodium and potassium in Dan Hong injection by atomic absorption spectrometry

To establish and validate the determination method of the content of sodium ion and potassium ion in Dan Hong injection by atomic absorption spectrometry (AAS). [Methods] Microwave digestion system was applied to deteriorate samples, and the content of sodium ion and potassium ion was determined by AAS. [Results] The calibration curve of sodium was liner (r=0.9998) in the range from 0.1to0.6mg/L. The average recovery was 101.1% with RSD 1.8%. The limit of detection was 5.3μg/L. The calibration curve of potassium was liner (r=0.9998) in the range from 0.1 to 0.8mg/L. The average recovery was 99.8%with RSD 2.3%. The limit of detection was 7.7μg/L. The determination results of 10 batches Dan Hong injection sample showed that the content of sodium ion was 562.3 to 734.7 mg/L and potassium ion was 206.9 to 314.4mg/L. [Conclusion] The method is simple and accurate and can be used for determination of the contents of sodiumion and potassium ion in Dan Hong injection. The accurate quantitative determination method can be promoted to quality control of Dan Hong injection

Authors

Institutions

Publication Details

Journal
Cambridge Science Advance
Published
2024-09-13
DOI
https://doi.org/10.62852/csa/2024/62
Primary Topic
Traditional Chinese Medicine Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of sodium and potassium in Dan Hong injection by atomic absorption spectrometry

Ling Xue, Zhu Yangbang, Qingguo Liu, Yun Wang
Cambridge Science Advance
Traditional Chinese Medicine Studies
article

Determination of sodium and potassium in Dan Hong injection by atomic absorption spectrometry

Ling Xue, Zhu Yangbang, Qingguo Liu, Yun Wang
article en

Abstract

To establish and validate the determination method of the content of sodium ion and potassium ion in Dan Hong injection by atomic absorption spectrometry (AAS). [Methods] Microwave digestion system was applied to deteriorate samples, and the content of sodium ion and potassium ion was determined by AAS. [Results] The calibration curve of sodium was liner (r=0.9998) in the range from 0.1to0.6mg/L. The average recovery was 101.1% with RSD 1.8%. The limit of detection was 5.3μg/L. The calibration curve of potassium was liner (r=0.9998) in the range from 0.1 to 0.8mg/L. The average recovery was 99.8%with RSD 2.3%. The limit of detection was 7.7μg/L. The determination results of 10 batches Dan Hong injection sample showed that the content of sodium ion was 562.3 to 734.7 mg/L and potassium ion was 206.9 to 314.4mg/L. [Conclusion] The method is simple and accurate and can be used for determination of the contents of sodiumion and potassium ion in Dan Hong injection. The accurate quantitative determination method can be promoted to quality control of Dan Hong injection

Cambridge Science AdvanceVol. 2024(4)
National Medical Products Administration (CN), Qingdao Institute of Bioenergy and Bioprocess Technology (CN)
Openalex Percentile: Top 70%
Traditional Chinese Medicine Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.