Damage source localisation in complex geometries using acoustic emission and acousto-ultrasonic techniques: an experimental study on clear aligners

Passive non-destructive evaluation tools such as acoustic emission (AE) testing and acousto-ultrasonics (AU) approach present a complex problem in damage localisation in complex and nonhomogeneous geometries. A novel AU-guided AE frequency interpretation approach is proposed in this research work which aims at overcoming this limitation. For the experimental evaluation, the damage sources from a geometrically complex clear dental aligners are tested under cyclic compression load and their origins are evaluated. Despite the rapid worldwide diffusion of the clear aligners, their mechanical behaviour is poorly investigated. In this work, the frequency characteristics of the artificially simulated stress wave, generated from different dental positions of the clear aligners, are studied using the AU approach. These frequency characteristics are then used to analyse the AE signals generated by these aligners when subjected to cyclic compressive loading. In addition, the time domain characteristics of the AE signals are studied using their Time of Arrival (ToA). The Akaike Information Criterion (AIC) is used to estimate the ToA. These frequency and time domain characteristics of the AE signals are used to estimate the local damage origin in the clear dental aligners. This will help in identifying localised damage sources during the usage period of the aligners. Experimental results revealed significant damages in the left maxillary premolar and right maxillary third molar of the aligners.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-09-14
DOI
https://doi.org/10.1038/s41598-024-72553-2
Citations
2
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Damage source localisation in complex geometries using acoustic emission and acousto-ultrasonic techniques: an experimental study on clear aligners

Domenico Ciavarella, Claudia Barile, Giovanni Pappalettera, Caterina Casavola et al.
2 citations
Scientific Reports
Ultrasonics and Acoustic Wave Propagation
0.54
article

Damage source localisation in complex geometries using acoustic emission and acousto-ultrasonic techniques: an experimental study on clear aligners

Domenico Ciavarella, Claudia Barile, Giovanni Pappalettera, Caterina Casavola, Michele Laurenziello, Claudia Cianci, Carmine Pappalettere, Vimalathithan Paramsamy Kannan
article en
2 citations

Abstract

Passive non-destructive evaluation tools such as acoustic emission (AE) testing and acousto-ultrasonics (AU) approach present a complex problem in damage localisation in complex and nonhomogeneous geometries. A novel AU-guided AE frequency interpretation approach is proposed in this research work which aims at overcoming this limitation. For the experimental evaluation, the damage sources from a geometrically complex clear dental aligners are tested under cyclic compression load and their origins are evaluated. Despite the rapid worldwide diffusion of the clear aligners, their mechanical behaviour is poorly investigated. In this work, the frequency characteristics of the artificially simulated stress wave, generated from different dental positions of the clear aligners, are studied using the AU approach. These frequency characteristics are then used to analyse the AE signals generated by these aligners when subjected to cyclic compressive loading. In addition, the time domain characteristics of the AE signals are studied using their Time of Arrival (ToA). The Akaike Information Criterion (AIC) is used to estimate the ToA. These frequency and time domain characteristics of the AE signals are used to estimate the local damage origin in the clear dental aligners. This will help in identifying localised damage sources during the usage period of the aligners. Experimental results revealed significant damages in the left maxillary premolar and right maxillary third molar of the aligners.

Scientific ReportsVol. 14(1)
University of Foggia (IT), Polytechnic University of Bari (IT)
European Commission, Ministero dell’Istruzione, dell’Università e della Ricerca
Climate action
Openalex Percentile: Top 40%
Ultrasonics and Acoustic Wave Propagation
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.