Research on solar-air source heat pump coupled heating system based on heat network in severe cold regions of China

• Coupled heating system combining renewable energy with traditional energy. • District heating multi-energy coupling (NH-SASHP) systems are used in cold regions. • The NH-SASHP is compared with the air source heat pump heating system(ASHP). In the application of clean energy heating, the development of a low-carbon winter heat supply in severe cold regions of China is hindered by the stability of heat sources. To ensure the smooth transformation of traditional energy to clean energy heating modes, the feasibility of a heating system coupling traditional and clean energies was studied using the heating system of an office building in a cold region of China as the research object. The air-source heat pump (ASHP) heating system used in the office building in this study was field-tested. The problems existing in the heating system were analysed using testing data combined with the existing conditions of the building. Solar-air source heat pump coupled heating system based on heat grid (NH-SASHP) was proposed, and the system model was established using TRNSYS software. The operation effect of the NH-SASHP coupling system was analysed, and the control strategy of the coupling system was optimized. The results showed that NH-SASHP system possessed certain advantages over the ASHP system during the heating season, and the energy saving rate is 50.79 % compared with the ASHP system. Under the most unfavourable working conditions in the middle of severe cold, the indoor temperature compliance rate was 100 %. The average coefficient of performance of the heat pump system (COP sys ) of NH-SASHP system and ASHP system were 6.27 and 3.55, respectively. The operating cost of the NH-SASHP system is approximately 72.3 % of the ASHP system.

Authors

Institutions

Publication Details

Journal
Energy and Built Environment
Published
2024-09-14
DOI
https://doi.org/10.1016/j.enbenv.2024.08.008
Citations
10
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on solar-air source heat pump coupled heating system based on heat network in severe cold regions of China

Kailiang Huang, Eric Y. Chuang, Xin Liu, Guohui Feng et al.
10 citations
Energy and Built Environment
Building Energy and Comfort Optimization
2.65
article

Research on solar-air source heat pump coupled heating system based on heat network in severe cold regions of China

Kailiang Huang, Eric Y. Chuang, Xin Liu, Guohui Feng, Yuqing Cui, Xinni Li, Xiaotong Wang
article en
10 citations

Abstract

• Coupled heating system combining renewable energy with traditional energy. • District heating multi-energy coupling (NH-SASHP) systems are used in cold regions. • The NH-SASHP is compared with the air source heat pump heating system(ASHP). In the application of clean energy heating, the development of a low-carbon winter heat supply in severe cold regions of China is hindered by the stability of heat sources. To ensure the smooth transformation of traditional energy to clean energy heating modes, the feasibility of a heating system coupling traditional and clean energies was studied using the heating system of an office building in a cold region of China as the research object. The air-source heat pump (ASHP) heating system used in the office building in this study was field-tested. The problems existing in the heating system were analysed using testing data combined with the existing conditions of the building. Solar-air source heat pump coupled heating system based on heat grid (NH-SASHP) was proposed, and the system model was established using TRNSYS software. The operation effect of the NH-SASHP coupling system was analysed, and the control strategy of the coupling system was optimized. The results showed that NH-SASHP system possessed certain advantages over the ASHP system during the heating season, and the energy saving rate is 50.79 % compared with the ASHP system. Under the most unfavourable working conditions in the middle of severe cold, the indoor temperature compliance rate was 100 %. The average coefficient of performance of the heat pump system (COP sys ) of NH-SASHP system and ASHP system were 6.27 and 3.55, respectively. The operating cost of the NH-SASHP system is approximately 72.3 % of the ASHP system.

Energy and Built EnvironmentVol. 7(1)
Shenyang Jianzhu University (CN)
Affordable and clean energy
Openalex Percentile: Top 11%
Building Energy and Comfort Optimization
2.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.