PERSAMAAN REGRESI LINIER BERGANDA UNTUK MEMPREDIKSI EFISIENSI BOILER

Boiler efficiency calculation is crucial to determine the reliability of boiler performance. Generally, boiler efficiency is calculated by the heat loss method, which considers losses in the combustion process. The calculation consumes more time due to detailed procedure and analysis. This research aims to develop a multiple linear regression equation in predicting boiler efficiency based on performance test data from PLTU X unit 1. The equation was then validated with a classical assumption test, i.e. normality, linearity, multicollinearity, heteroscedasticity, autocorrelation, and hypothesis test. In addition, the equation was used to calculate the boiler efficiency at PLTU ABC (unit 1 & 2) and PLTU XYZ (unit 1). The results show that there is approximately 0.49% boiler efficiency discrepancy among equation and heat loss method calculations.

Authors

Institutions

Publication Details

Journal
Jurnal Rekayasa Mesin
Published
2024-08-15
DOI
https://doi.org/10.21776/jrm.v15i2.1179
Primary Topic
Heat Transfer and Numerical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PERSAMAAN REGRESI LINIER BERGANDA UNTUK MEMPREDIKSI EFISIENSI BOILER

Martin Choirul Fatah, I. Made Brunner, Eko Sarwono
Jurnal Rekayasa Mesin
Heat Transfer and Numerical Methods
article

PERSAMAAN REGRESI LINIER BERGANDA UNTUK MEMPREDIKSI EFISIENSI BOILER

Martin Choirul Fatah, I. Made Brunner, Eko Sarwono
article en

Abstract

Boiler efficiency calculation is crucial to determine the reliability of boiler performance. Generally, boiler efficiency is calculated by the heat loss method, which considers losses in the combustion process. The calculation consumes more time due to detailed procedure and analysis. This research aims to develop a multiple linear regression equation in predicting boiler efficiency based on performance test data from PLTU X unit 1. The equation was then validated with a classical assumption test, i.e. normality, linearity, multicollinearity, heteroscedasticity, autocorrelation, and hypothesis test. In addition, the equation was used to calculate the boiler efficiency at PLTU ABC (unit 1 & 2) and PLTU XYZ (unit 1). The results show that there is approximately 0.49% boiler efficiency discrepancy among equation and heat loss method calculations.

Jurnal Rekayasa MesinVol. 15(2)
Institut Teknologi Indonesia (ID), Institut Teknologi PLN
Openalex Percentile: Top 83%
Heat Transfer and Numerical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PERSAMAAN REGRESI LINIER BERGANDA UNTUK MEMPREDIKSI EFISIENSI BOILER — Martin Choirul Fatah, I. Made Brunner, et al. · Jurnal Rekayasa Mesin (2024) | TGRS Research Map | TGRS