Titanium patient-specific scaphoid replacement for unreconstructable nonunions: a case series study

Although reconstruction is the preferred treatment option for symptomatic scaphoid nonunions, this may not be an option due to inadequate bone quality or degenerative changes. Existing salvage procedures tend to compromise function. This study introduces an alternative approach through the utilisation of a 3-D-printed titanium patient-specific scaphoid implant. In this retrospective case series, the outcomes of 12 patients treated for an unreconstructable scaphoid nonunion with a 3-D-printed prosthesis were evaluated. Patient-reported outcomes, range of motion, grip strength and plain radiographs were assessed pre- and postoperatively. The mean follow-up was 2 years and 8 months. Range of movement and patient-reported outcome scores improved postoperatively, although improvement in movement was not significant. Except for one, all implants showed satisfactory alignment on radiographs without any further degenerative changes. 3-D-printed titanium scaphoid replacement may be an alternative to salvage procedures for unreconstructable scaphoid nonunion.<b>Level of evidence:</b> IV.

Authors

Institutions

Publication Details

Journal
Journal of Hand Surgery (European Volume)
Published
2024-09-14
DOI
https://doi.org/10.1177/17531934241276375
Citations
7
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Titanium patient-specific scaphoid replacement for unreconstructable nonunions: a case series study

Eline Stroobants, Andreas Verstreken, Frederik Verstreken, Willem Geuskens
7 citations
Journal of Hand Surgery (European Volume)
Orthopedic Surgery and Rehabilitation
4.01
article

Titanium patient-specific scaphoid replacement for unreconstructable nonunions: a case series study

Eline Stroobants, Andreas Verstreken, Frederik Verstreken, Willem Geuskens
article en
7 citations

Abstract

Although reconstruction is the preferred treatment option for symptomatic scaphoid nonunions, this may not be an option due to inadequate bone quality or degenerative changes. Existing salvage procedures tend to compromise function. This study introduces an alternative approach through the utilisation of a 3-D-printed titanium patient-specific scaphoid implant. In this retrospective case series, the outcomes of 12 patients treated for an unreconstructable scaphoid nonunion with a 3-D-printed prosthesis were evaluated. Patient-reported outcomes, range of motion, grip strength and plain radiographs were assessed pre- and postoperatively. The mean follow-up was 2 years and 8 months. Range of movement and patient-reported outcome scores improved postoperatively, although improvement in movement was not significant. Except for one, all implants showed satisfactory alignment on radiographs without any further degenerative changes. 3-D-printed titanium scaphoid replacement may be an alternative to salvage procedures for unreconstructable scaphoid nonunion.<b>Level of evidence:</b> IV.

Journal of Hand Surgery (European Volume)Vol. 50(4)
University of Antwerp (BE), Universitair Ziekenhuis Leuven (BE)
Openalex Percentile: Top 6%
Orthopedic Surgery and Rehabilitation
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.