ANALISIS PENGARUH BENTUK LUBANG TERHADAP KARAKTERISTIK PERPINDAHAN PANAS PADA MENARA PENDINGIN TIPE PLAT DATAR BERLUBANG BERTINGKAT

Cooling tower is one of the most widely used cooling systems in the industrial world. A cooling tower is a series of heat exchange devices that use working fluids, such as water and air, to act as a cooling medium by coming into direct contact with the air, causing a small portion of the water to evaporate and reducing the temperature of the liquid. To enhance the performance of cooling towers, many researchers have conducted studies on this matter, but there is still room for improvement to achieve more optimal results. The objective of this research is to obtain an optimal cooling tower system by determining the convective heat transfer coefficient. With this phenomenon, the research investigates the heat transfer process that occurs on perforated plates in a flat plate-type cooling tower with an overall tower height of approximately 2.4 meters and around 5 levels of fluid distribution media. The length of each plate is 0.7 meters with a width of 0.5 meters. Variations are also made in the multi-level cooling tower design, specifically in the shape of the perforations used, including circular, triangular, and square perforation shapes, using a zig-zag outlet hole model. The perforated plate area is 0.0157 square meters for each plate, with a 15° inclination angle for each plate arrangement. The research results indicate that the highest heat transfer coefficient values occur in the multi-level cooling tower when using square-shaped plates, followed by triangular-shaped plates, while circular-shaped plates have the lowest heat transfer coefficient values. Therefore, variations in the shape of the perforations on the flat plates affect the change in temperature reduction and the heat transfer coefficient values in the performance of the multi-level cooling tower.

Authors

Institutions

Publication Details

Journal
Jurnal Rekayasa Mesin
Published
2024-08-15
DOI
https://doi.org/10.21776/jrm.v15i2.1699
Citations
1
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISIS PENGARUH BENTUK LUBANG TERHADAP KARAKTERISTIK PERPINDAHAN PANAS PADA MENARA PENDINGIN TIPE PLAT DATAR BERLUBANG BERTINGKAT

Ahmad Syuhada, Razali Razali, Yulanda Dwi Mustika
1 citations
Jurnal Rekayasa Mesin
Adsorption and Cooling Systems
0.21
article

ANALISIS PENGARUH BENTUK LUBANG TERHADAP KARAKTERISTIK PERPINDAHAN PANAS PADA MENARA PENDINGIN TIPE PLAT DATAR BERLUBANG BERTINGKAT

Ahmad Syuhada, Razali Razali, Yulanda Dwi Mustika
article en
1 citations

Abstract

Cooling tower is one of the most widely used cooling systems in the industrial world. A cooling tower is a series of heat exchange devices that use working fluids, such as water and air, to act as a cooling medium by coming into direct contact with the air, causing a small portion of the water to evaporate and reducing the temperature of the liquid. To enhance the performance of cooling towers, many researchers have conducted studies on this matter, but there is still room for improvement to achieve more optimal results. The objective of this research is to obtain an optimal cooling tower system by determining the convective heat transfer coefficient. With this phenomenon, the research investigates the heat transfer process that occurs on perforated plates in a flat plate-type cooling tower with an overall tower height of approximately 2.4 meters and around 5 levels of fluid distribution media. The length of each plate is 0.7 meters with a width of 0.5 meters. Variations are also made in the multi-level cooling tower design, specifically in the shape of the perforations used, including circular, triangular, and square perforation shapes, using a zig-zag outlet hole model. The perforated plate area is 0.0157 square meters for each plate, with a 15° inclination angle for each plate arrangement. The research results indicate that the highest heat transfer coefficient values occur in the multi-level cooling tower when using square-shaped plates, followed by triangular-shaped plates, while circular-shaped plates have the lowest heat transfer coefficient values. Therefore, variations in the shape of the perforations on the flat plates affect the change in temperature reduction and the heat transfer coefficient values in the performance of the multi-level cooling tower.

Jurnal Rekayasa MesinVol. 15(2)
Universitas Syiah Kuala (ID)
Openalex Percentile: Top 52%
Adsorption and Cooling Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.