ANALISIS KINERJA KOMPOR GAS BERBAHAN BAKAR DIMETHYL ETHER DENGAN VARIASI DIAMETER LUBANG ANGIN PADA NOSEL

The use of a vent on a gas stove affects the mixing of air with fuel. This study examines the effect of different vent diameters on the performance of Dimethyl Ether (DME) gas-fueled stoves. A nozzle with variations in vent diameter of 3 mm, 2 mm, 1 mm, and no vent with a nozzle diameter of 0.96 mm at each vent. Installed on the fuel ignition system, the flame, heat intake, and combustion efficiency were tested. From the test results at a pressure of 280 mmH2O, the highest flame noise value after shutdown was obtained at the nozzle with a 1 mm vent which amounted to 64.2 dB, the highest heat intake value at the nozzle with a 1 mm vent which amounted to 1.6625 kW, and the highest efficiency value at the nozzle with a 3 mm vent which amounted to 59.135%.

Authors

Institutions

Publication Details

Journal
Jurnal Rekayasa Mesin
Published
2024-08-15
DOI
https://doi.org/10.21776/jrm.v15i2.1662
Primary Topic
Natural Products and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISIS KINERJA KOMPOR GAS BERBAHAN BAKAR DIMETHYL ETHER DENGAN VARIASI DIAMETER LUBANG ANGIN PADA NOSEL

Rany Puspita Dewi, Sigit Iswahyudi, Seno Sutrisno
Jurnal Rekayasa Mesin
Natural Products and Applications
article

ANALISIS KINERJA KOMPOR GAS BERBAHAN BAKAR DIMETHYL ETHER DENGAN VARIASI DIAMETER LUBANG ANGIN PADA NOSEL

Rany Puspita Dewi, Sigit Iswahyudi, Seno Sutrisno
article en

Abstract

The use of a vent on a gas stove affects the mixing of air with fuel. This study examines the effect of different vent diameters on the performance of Dimethyl Ether (DME) gas-fueled stoves. A nozzle with variations in vent diameter of 3 mm, 2 mm, 1 mm, and no vent with a nozzle diameter of 0.96 mm at each vent. Installed on the fuel ignition system, the flame, heat intake, and combustion efficiency were tested. From the test results at a pressure of 280 mmH2O, the highest flame noise value after shutdown was obtained at the nozzle with a 1 mm vent which amounted to 64.2 dB, the highest heat intake value at the nozzle with a 1 mm vent which amounted to 1.6625 kW, and the highest efficiency value at the nozzle with a 3 mm vent which amounted to 59.135%.

Jurnal Rekayasa MesinVol. 15(2)
Universitas Tidar (ID)
Openalex Percentile: Top 72%
Natural Products and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALISIS KINERJA KOMPOR GAS BERBAHAN BAKAR DIMETHYL ETHER DENGAN VARIASI DIAMETER LUBANG ANGIN PADA NOSEL — Rany Puspita Dewi, Sigit Iswahyudi, et al. · Jurnal Rekayasa Mesin (2024) | TGRS Research Map | TGRS