Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters

This study compares air pollutant concentrations resulting from cooking with gas or induction cooktops, with or without either of two recirculating range hoods with filters. A meal of pasta, plant-based “meat” sauce and stir-fried broccoli was cooked three times for each cooktop and hood combination in a 158 m 3 room. Time-resolved measurements were made of nitrogen oxides (NO X ), carbon dioxide (CO 2 ), size-resolved particles, and speciated volatile organic compounds (VOCs) during cooking and 30 minutes after cooking. Cooking with induction used half as much energy, produced no discernible NO X , and significantly reduced ultrafine particles (UFP, diameter < 100 nm) and CO 2 compared to gas cooktops. Induction produced statistically higher PM 2.5 when calculated using size-resolved particle measurements from one pair of instruments, but the difference was not discernible when calculating from another pair. With gas cooktops, roughly half of the PM 2.5 was in particles smaller than 0.3 μm and thus below the lower quantitation threshold for many optical particle instruments; optical devices may thus substantially under-report PM 2.5 from gas cooking. VOCs did not significantly differ between gas and induction. Both recirculating range hoods substantially reduced all particle sizes when cooking with either fuel, and the reductions were larger for gas cooking. One of the range hoods also substantially lowered some of the VOCs. • Measured air pollutants from cooking a simple meal with gas or induction cooktop. • Induction used 50 % less energy, emitted no NOX and fewer ultrafine particles. • Cooking this meal with induction likely emitted more PM2.5. • Half of the gas-cooking PM2.5 was under the optical sensor threshold of 0.3 μm. • Both recirculating range hoods with filters substantially reduced particle levels.

Authors

Institutions

Publication Details

Journal
Indoor Environments
Published
2024-09-14
DOI
https://doi.org/10.1016/j.indenv.2024.100047
Citations
6
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
1.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters

Xiaochen Tang, William W. Delp, Haoran Zhao, Marion Russell et al.
6 citations
Indoor Environments
Air Quality Monitoring and Forecasting
1.23
article

Air pollutant exposure concentrations from cooking a meal with a gas or induction cooktop and the effectiveness of two recirculating range hoods with filters

Xiaochen Tang, William W. Delp, Haoran Zhao, Marion Russell, Brett C. Singer, Iain S. Walker, Alexandra Johnson, Jiayu Li
article en
6 citations

Abstract

This study compares air pollutant concentrations resulting from cooking with gas or induction cooktops, with or without either of two recirculating range hoods with filters. A meal of pasta, plant-based “meat” sauce and stir-fried broccoli was cooked three times for each cooktop and hood combination in a 158 m 3 room. Time-resolved measurements were made of nitrogen oxides (NO X ), carbon dioxide (CO 2 ), size-resolved particles, and speciated volatile organic compounds (VOCs) during cooking and 30 minutes after cooking. Cooking with induction used half as much energy, produced no discernible NO X , and significantly reduced ultrafine particles (UFP, diameter < 100 nm) and CO 2 compared to gas cooktops. Induction produced statistically higher PM 2.5 when calculated using size-resolved particle measurements from one pair of instruments, but the difference was not discernible when calculating from another pair. With gas cooktops, roughly half of the PM 2.5 was in particles smaller than 0.3 μm and thus below the lower quantitation threshold for many optical particle instruments; optical devices may thus substantially under-report PM 2.5 from gas cooking. VOCs did not significantly differ between gas and induction. Both recirculating range hoods substantially reduced all particle sizes when cooking with either fuel, and the reductions were larger for gas cooking. One of the range hoods also substantially lowered some of the VOCs. • Measured air pollutants from cooking a simple meal with gas or induction cooktop. • Induction used 50 % less energy, emitted no NOX and fewer ultrafine particles. • Cooking this meal with induction likely emitted more PM2.5. • Half of the gas-cooking PM2.5 was under the optical sensor threshold of 0.3 μm. • Both recirculating range hoods with filters substantially reduced particle levels.

Indoor EnvironmentsVol. 1(4)
Lawrence Berkeley National Laboratory (US), University of California, Berkeley (US)
U.S. Environmental Protection Agency, Office of Energy Efficiency and Renewable Energy
Zero hunger
Openalex Percentile: Top 23%
Air Quality Monitoring and Forecasting
1.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.