Techno-economic analysis of a hybrid energy system for electrification using an off-grid solar/biogas/battery system employing HOMER: A case study in Vietnam

The electrification of off-grid /island villages is a critical step towards improving the techno-economic circumstances of rural regions and the overall general growth of the country. However, consistent supply from a single source is not possible in these areas. Thus, a hybrid renewable energy system performs better in these conditions. The research challenge now is to identify the optimal combinations of HRES from the available resources in a specific village site that can supply the power demand sustainably and to determine whether this is a cost-effective option. The present work is an endeavour to develop a sustainable and dynamic energy demand-supply model using HOMER Pro energy software in a specified off-grid rural site in Vietnam. The research presents four unique configurations of a combined energy system for Vietnam's island settlements, incorporating biomass-based biogas facilities, photovoltaic panels , lithium-ion batteries, and converters. Homer Pro was used for optimization and design, focusing on key performance measures such as cost of energy, net present cost, initial cost, operating cost, renewable fraction, and carbon emissions . The best HES system layout includes a 100-kW biomass-based generator, 2.62 kW photovoltaic installation, 10 lithium-ion batteries, and a 6.31 kW converter, producing 100 % renewable energy . The system's low cost of energy ($0.48), and net present cost ($25,730.89) make it an economically viable alternative, while its low CO 2 emissions demonstrate its commitment to reducing greenhouse gas emissions . • Hybrid renewable energy solutions outperform single-source supply. • Sustainable and dynamic energy demand-supply model using HOMER Pro • Proposed hybrid energy system includes biomass, PV, batteries, and converters. • Proposed configuration is 100 % renewable, cost-effective, and low in CO 2 .

Authors

Institutions

Publication Details

Journal
Process Safety and Environmental Protection
Published
2024-09-14
DOI
https://doi.org/10.1016/j.psep.2024.09.046
Citations
44
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
7.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Techno-economic analysis of a hybrid energy system for electrification using an off-grid solar/biogas/battery system employing HOMER: A case study in Vietnam

Prabhakar Sharma, Thi Minh Tu Bui, Sameh M. Osman, Van Huong Dong et al.
44 citations
Process Safety and Environmental Protection
Hybrid Renewable Energy Systems
7.46
article

Techno-economic analysis of a hybrid energy system for electrification using an off-grid solar/biogas/battery system employing HOMER: A case study in Vietnam

Prabhakar Sharma, Thi Minh Tu Bui, Sameh M. Osman, Van Huong Dong, Bhaskor Jyoti Bora, Dao Nam Cao, Van Giao Nguyen, Jerzy Kowalski, Cristina Efremov, Minh Ho Tran
article en
44 citations

Abstract

The electrification of off-grid /island villages is a critical step towards improving the techno-economic circumstances of rural regions and the overall general growth of the country. However, consistent supply from a single source is not possible in these areas. Thus, a hybrid renewable energy system performs better in these conditions. The research challenge now is to identify the optimal combinations of HRES from the available resources in a specific village site that can supply the power demand sustainably and to determine whether this is a cost-effective option. The present work is an endeavour to develop a sustainable and dynamic energy demand-supply model using HOMER Pro energy software in a specified off-grid rural site in Vietnam. The research presents four unique configurations of a combined energy system for Vietnam's island settlements, incorporating biomass-based biogas facilities, photovoltaic panels , lithium-ion batteries, and converters. Homer Pro was used for optimization and design, focusing on key performance measures such as cost of energy, net present cost, initial cost, operating cost, renewable fraction, and carbon emissions . The best HES system layout includes a 100-kW biomass-based generator, 2.62 kW photovoltaic installation, 10 lithium-ion batteries, and a 6.31 kW converter, producing 100 % renewable energy . The system's low cost of energy ($0.48), and net present cost ($25,730.89) make it an economically viable alternative, while its low CO 2 emissions demonstrate its commitment to reducing greenhouse gas emissions . • Hybrid renewable energy solutions outperform single-source supply. • Sustainable and dynamic energy demand-supply model using HOMER Pro • Proposed hybrid energy system includes biomass, PV, batteries, and converters. • Proposed configuration is 100 % renewable, cost-effective, and low in CO 2 .

Process Safety and Environmental ProtectionVol. 191
University of Delhi (IN), Ho Chi Minh City University of Transport (VN), Gdańsk University of Technology (PL), Technical University of Moldova (MD), King Saud University (SA), University of Da Nang (VN), University of Gdańsk (PL), HUTECH University, Ho Chi Minh City University of Technology (VN), Rajiv Gandhi Institute of Petroleum Technology (IN)
Affordable and clean energy
Openalex Percentile: Top 2%
Hybrid Renewable Energy Systems
7.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.