Novel supraglottic airway device for ophthalmic procedures

Dear Editor, Ophthalmic procedures like strabismus surgery, vitreoretinal surgery and laser indirect ophthalmoscopy are frequently performed in the paediatric age group. Supraglottic airway devices (SADs) are commonly used for ophthalmic procedures. However, there are chances of dislodgement or displacement of SADs with rigid and protruding air tube due to the hand movements of the ophthalmologist in the vicinity.[1,2] To address this concern, we wanted to increase the angulation of the air tube of SAD at the lip, so that the air tube can be directed towards the chin. To achieve this goal, we ingeniously combined two (1.0; 1.5 and 1.5; 2.0) sizes of AMBU® AURA 40TM reusable laryngeal mask (LM) (AMBU A/S, Ballerup, Denmark) [Figure 1]. Smaller-sized AMBU® AURA 40TM LM was cut just beyond the end of the inflation line, and larger-sized AMBU® AURA 40TM LM was cut to use the curvature part. Then, both AMBU® AURA 40TM LMs were joined, so that larger AMBU® covered the smaller AMBU®, forming a device that provided an optimal angle at the lip. We took care to have a joint at the level of the lip to observe any disconnections [Figure 1b]. This device is easy to insert and allows ophthalmologists to perform eye surgeries without discomfort to access the desired surgical field and without risk of displacement of SAD [Figure 1d]. We have used this novel device in 50 preterm and ex-premature infants weighing more than 3.0 kg with spontaneous and controlled ventilation without any undue increase in airway pressure, end-tidal carbon dioxide or decreased expired tidal volume and with excellent surgeon’s satisfaction.Figure 1: (a) Novel supraglottic airway device. (b and c) Novel supraglottic airway device in situ depicting joint outside the lip with angulation. (d) Maneuverability of ophthalmologist during laser indirect ophthalmoscopySince it is an indigenous device and has not undergone any rigorous safety evaluation, it should be used only when other devices are not available due to medical and safety concerns, such as the risk of disconnection, loosening of joints, and gas leaks. Declaration of Patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient consented to the images and other clinical information being reported in the journal. The patient understands that his name and initials will not be published and due efforts will be made to conceal his identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Authors

Institutions

Publication Details

Journal
Indian Journal of Anaesthesia
Published
2024-09-14
DOI
https://doi.org/10.4103/ija.ija_537_24
Citations
1
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel supraglottic airway device for ophthalmic procedures

Kanil Ranjith Kumar, Arshad Ayub, Renu Sinha, Vinay Balnath Gaikwad
1 citations
Indian Journal of Anaesthesia
Airway Management and Intubation Techniques
0.64
article

Novel supraglottic airway device for ophthalmic procedures

Kanil Ranjith Kumar, Arshad Ayub, Renu Sinha, Vinay Balnath Gaikwad
article en
1 citations

Abstract

Dear Editor, Ophthalmic procedures like strabismus surgery, vitreoretinal surgery and laser indirect ophthalmoscopy are frequently performed in the paediatric age group. Supraglottic airway devices (SADs) are commonly used for ophthalmic procedures. However, there are chances of dislodgement or displacement of SADs with rigid and protruding air tube due to the hand movements of the ophthalmologist in the vicinity.[1,2] To address this concern, we wanted to increase the angulation of the air tube of SAD at the lip, so that the air tube can be directed towards the chin. To achieve this goal, we ingeniously combined two (1.0; 1.5 and 1.5; 2.0) sizes of AMBU® AURA 40TM reusable laryngeal mask (LM) (AMBU A/S, Ballerup, Denmark) [Figure 1]. Smaller-sized AMBU® AURA 40TM LM was cut just beyond the end of the inflation line, and larger-sized AMBU® AURA 40TM LM was cut to use the curvature part. Then, both AMBU® AURA 40TM LMs were joined, so that larger AMBU® covered the smaller AMBU®, forming a device that provided an optimal angle at the lip. We took care to have a joint at the level of the lip to observe any disconnections [Figure 1b]. This device is easy to insert and allows ophthalmologists to perform eye surgeries without discomfort to access the desired surgical field and without risk of displacement of SAD [Figure 1d]. We have used this novel device in 50 preterm and ex-premature infants weighing more than 3.0 kg with spontaneous and controlled ventilation without any undue increase in airway pressure, end-tidal carbon dioxide or decreased expired tidal volume and with excellent surgeon’s satisfaction.Figure 1: (a) Novel supraglottic airway device. (b and c) Novel supraglottic airway device in situ depicting joint outside the lip with angulation. (d) Maneuverability of ophthalmologist during laser indirect ophthalmoscopySince it is an indigenous device and has not undergone any rigorous safety evaluation, it should be used only when other devices are not available due to medical and safety concerns, such as the risk of disconnection, loosening of joints, and gas leaks. Declaration of Patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient consented to the images and other clinical information being reported in the journal. The patient understands that his name and initials will not be published and due efforts will be made to conceal his identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Indian Journal of AnaesthesiaVol. 68(10)
All India Institute of Medical Sciences (IN)
Openalex Percentile: Top 28%
Airway Management and Intubation Techniques
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.