Application of ISO 16140-3:2021 – Key Concepts and Examples of Verification of Alternative Methods

Verification of the methods routinely used in the laboratory is a requirement for laboratories accredited to the International Organization for Standardization (ISO) standard: ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.1 A method verification protocol is not specified within the ISO 17025:2017 standard, and until now, laboratories have been required to conduct their verification studies based on protocols either developed in-house, or using locally recognized protocols, such as: NATA Technical Note 17,2 Health Canada Compendium of Methods,3 etc. The publication of ISO 16140-3:2021 Microbiology of the food chain — Method validation — Part 3: Protocol for the verification of reference methods and validated alternative methods in a single laboratory4 now provides an internationally developed and recognized protocol that may be used to fulfill this requirement. An orientation to some of the key concepts within the ISO 16140-3:2021 standard is presented and demonstrated using examples of verification of both a qualitative method (Neogen® Molecular Detection Assay 2 – Salmonella (MDA2 SAL) and a quantitative method Neogen® Petrifilm® Enterobacteriaceae Count Plate (Petrifilm EB Plate).

Authors

Publication Details

Published
2024-09-13
DOI
https://doi.org/10.55459/ijca/v3i1/db
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of ISO 16140-3:2021 – Key Concepts and Examples of Verification of Alternative Methods

DeAnn Benesh
SARS-CoV-2 detection and testing
article

Application of ISO 16140-3:2021 – Key Concepts and Examples of Verification of Alternative Methods

DeAnn Benesh
article en

Abstract

Verification of the methods routinely used in the laboratory is a requirement for laboratories accredited to the International Organization for Standardization (ISO) standard: ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories.1 A method verification protocol is not specified within the ISO 17025:2017 standard, and until now, laboratories have been required to conduct their verification studies based on protocols either developed in-house, or using locally recognized protocols, such as: NATA Technical Note 17,2 Health Canada Compendium of Methods,3 etc. The publication of ISO 16140-3:2021 Microbiology of the food chain — Method validation — Part 3: Protocol for the verification of reference methods and validated alternative methods in a single laboratory4 now provides an internationally developed and recognized protocol that may be used to fulfill this requirement. An orientation to some of the key concepts within the ISO 16140-3:2021 standard is presented and demonstrated using examples of verification of both a qualitative method (Neogen® Molecular Detection Assay 2 – Salmonella (MDA2 SAL) and a quantitative method Neogen® Petrifilm® Enterobacteriaceae Count Plate (Petrifilm EB Plate).

Vol. 3(1)
Partnerships for the goals
Openalex Percentile: Top 81%
SARS-CoV-2 detection and testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.