Assessing the Electrochemical Performance of a Novel Low‐Cost Screen‐Printed Electrode Based on <i>Apis mellifera</i> Beeswax Modified with Vulcan@Chitosan Used for Acetominophen Detection

Abstract The present work reports the development of a highly sensitive electrochemical platform, constructed using screen printed electrode based on Apis mellifera beeswax (SPWE) – employed as substrate, and its application for acetaminophen (AC) detection. The sensor was produced using graphite ink and varnish glass solubilized in acetone. The SPWE was modified with a dispersion of chitosan (0.5% m/v) − functionalized Vulcan XC72R carbon black (Vulcan@Chitosan). Electrochemical characterization was performed using cyclic voltammetry (−0.7 to +0.8 V vs . pseudo‐graphite) and chronoamperometry in 0.1 mol L −1 KCl in the presence of 1.0 mmol L −1 [Fe(CN) 6 ] 3− /[Fe(CN) 6 ] 4− . Through the application of differential pulse voltammetry (DPV) using 0.1 mol L −1 PBS at pH 6.5, the proposed SPWE/Vulcan@Chitosan sensor was found to exhibit significant improvements in current response relative to the AC electrochemical detection. The sensor exhibited linear dynamic range of 0.05 to 4.0 μmol L −1 (n= 3), with R 2 = 0.992 and theorical LOD of 0.013 μmol L −1 (RSD= 3.80%). The AC detection was conducted in real matrices of river water, synthetic urine and synthetic saliva using the DPV technique yielded a mean recovery rate of 103% (RSD= 3.52%), exhibiting a high degree of accuracy. The SPWE/Vulcan@Chitosan electrochemical platform demonstrated high stability, good reproducibility and satisfactory repeatability; the current responses were not affected by the reutilization of the beeswax substrate for the production of new electrode. The findings of this study show that the proposed modified electrode is a simple, low‐cost sensing device which has proven to be highly efficient when applied for the AC detection in different matrices.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2024-09-12
DOI
https://doi.org/10.1002/elan.202400227
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Electrochemical Performance of a Novel Low‐Cost Screen‐Printed Electrode Based on Apis mellifera Beeswax Modified with Vulcan@Chitosan Used for Acetominophen Detection

Adriana Evaristo de Carvalho, Willyam R.P. Barros, Fernando C. Gallina, Adriana C. da Silva et al.
5 citations
Electroanalysis
Electrochemical sensors and biosensors
1.04
article

Assessing the Electrochemical Performance of a Novel Low‐Cost Screen‐Printed Electrode Based on Apis mellifera Beeswax Modified with Vulcan@Chitosan Used for Acetominophen Detection

Adriana Evaristo de Carvalho, Willyam R.P. Barros, Fernando C. Gallina, Adriana C. da Silva, Igor Gabriel Oliveira
article en
5 citations

Abstract

Abstract The present work reports the development of a highly sensitive electrochemical platform, constructed using screen printed electrode based on Apis mellifera beeswax (SPWE) – employed as substrate, and its application for acetaminophen (AC) detection. The sensor was produced using graphite ink and varnish glass solubilized in acetone. The SPWE was modified with a dispersion of chitosan (0.5% m/v) − functionalized Vulcan XC72R carbon black (Vulcan@Chitosan). Electrochemical characterization was performed using cyclic voltammetry (−0.7 to +0.8 V vs . pseudo‐graphite) and chronoamperometry in 0.1 mol L −1 KCl in the presence of 1.0 mmol L −1 [Fe(CN) 6 ] 3− /[Fe(CN) 6 ] 4− . Through the application of differential pulse voltammetry (DPV) using 0.1 mol L −1 PBS at pH 6.5, the proposed SPWE/Vulcan@Chitosan sensor was found to exhibit significant improvements in current response relative to the AC electrochemical detection. The sensor exhibited linear dynamic range of 0.05 to 4.0 μmol L −1 (n= 3), with R 2 = 0.992 and theorical LOD of 0.013 μmol L −1 (RSD= 3.80%). The AC detection was conducted in real matrices of river water, synthetic urine and synthetic saliva using the DPV technique yielded a mean recovery rate of 103% (RSD= 3.52%), exhibiting a high degree of accuracy. The SPWE/Vulcan@Chitosan electrochemical platform demonstrated high stability, good reproducibility and satisfactory repeatability; the current responses were not affected by the reutilization of the beeswax substrate for the production of new electrode. The findings of this study show that the proposed modified electrode is a simple, low‐cost sensing device which has proven to be highly efficient when applied for the AC detection in different matrices.

ElectroanalysisVol. 36(12)
Universidade Federal da Grande Dourados (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.