Multi-sensor integration on one microfluidics chip for single-stranded DNA detection
Purpose This study aims to improve detection efficiency of fluorescence biosensor or a graphene field-effect transistor biosensor. Graphene field-effect transistor biosensing and fluorescent biosensing were integrated and combined with magnetic nanoparticles to construct a multi-sensor integrated microfluidic biochip for detecting single-stranded DNA. Multi-sensor integrated biochip demonstrated higher detection reliability for a single target and could simultaneously detect different targets. Design/methodology/approach In this study, the authors integrated graphene field-effect transistor biosensing and fluorescent biosensing, combined with magnetic nanoparticles, to fabricate a multi-sensor integrated microfluidic biochip for the detection of single-stranded deoxyribonucleic acid (DNA). Graphene films synthesized through chemical vapor deposition were transferred onto a glass substrate featuring two indium tin oxide electrodes, thus establishing conductive channels for the graphene field-effect transistor. Using π-π stacking, 1-pyrenebutanoic acid succinimidyl ester was immobilized onto the graphene film to serve as a medium for anchoring the probe aptamer. The fluorophore-labeled target DNA subsequently underwent hybridization with the probe aptamer, thereby forming a fluorescence detection channel. Findings This paper presents a novel approach using three channels of light, electricity and magnetism for the detection of single-stranded DNA, accompanied by the design of a microfluidic detection platform integrating biosensor chips. Remarkably, the detection limit achieved is 10 pm, with an impressively low relative standard deviation of 1.007%. Originality/value By detecting target DNA, the photo-electro-magnetic multi-sensor graphene field-effect transistor biosensor not only enhances the reliability and efficiency of detection but also exhibits additional advantages such as compact size, affordability, portability and straightforward automation. Real-time display of detection outcomes on the host facilitates a deeper comprehension of biochemical reaction dynamics. Moreover, besides detecting the same target, the sensor can also identify diverse targets, primarily leveraging the penetrative and noninvasive nature of light.
Authors
- Xiaofeng Zhu (ORCID: https://orcid.org/0000-0003-0037-411X)
- Huanqing Liu
- Yue Ding (ORCID: https://orcid.org/0000-0002-5665-4877)
- Muhammad Shafi (ORCID: https://orcid.org/0000-0002-0381-4646)
- Shuqi Xie
- Cong Liu (ORCID: https://orcid.org/0000-0001-8190-2919)
- Weiwei Yue (ORCID: https://orcid.org/0000-0002-6042-0467)
- Yuwei Cao
- Yan Jing Ding
- Kang Ning Cheng
Institutions
- Shandong Normal University (CN)
- Southern University of Science and Technology (CN)
Publication Details
- Journal
- Sensor Review
- Published
- 2024-09-13
- DOI
- https://doi.org/10.1108/sr-06-2024-0562
- Citations
- 2
- Primary Topic
- Microfluidic and Capillary Electrophoresis Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.37