Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study

This study aims to compare the efficiencies of three noninvasive technologies in monitoring the perioperative hemodynamics of children with congenital heart disease (CHD) including ventricular septal defects with or without atrial septal defects. Three noninvasive technologies included transthoracic echocardiography (TTE), electrical cardiometry (EC), and vasoactive inotropic score (VIS). Parameters included left ventricular ejection fraction (LVEF) and cardiac index (cardiac index monitored by ultrasound, uCI) in TTE, cardiac index (cardiac index monitored by electrical cardiometry, eCI) and systemic vascular resistance index (SVRI) in EC, and VIS. Seventy-four children were eligible. Three types of adverse events (AEs) related to disease activity and prognosis were observed, including cardio-pulmonary resuscitation in five cases (5/74, 6.76%), hypoxic-ischemic brain damage in four cases (4/74, 5.41%) and hemopurification in four cases (4/74, 5.41%). Except for LVEF, eight parameters (VISmax [maximum VIS], VISmea [mean VIS], uCImea [mean uCI], uCImin [minimum uCI], eCImea [mean eCI], eCImin [minimum eCI], SVRImea [mean SVRI], and SVRImin [minimum SVRI]) showed predictive value for any AE (<i>p</i> < 0.05). VISmea, uCImea, and eCImea demonstrated the highest accuracy and linear associations (AUROC > 0.9, <i>p</i> = 0.00). Linear associations also existed between the three groups of parameters and the duration of mechanical ventilation (MV) and the length of stay (LOS) in the intensive care unit (ICU). The duration of MV and the LOS in the ICU increased as VISmea rose, or uCImea and eCImea fell (<i>p</i> < 0.05). LVEF in TTE could not predict any AE (<i>p</i> > 0.05) and not fully reflect the cardiovascular function. Therefore, most parameters obtained in TTE, EC, and VIS can reflect the perioperative hemodynamics of children with CHD, with VISmea, uCImea, and eCImea being most accurate.

Authors

Institutions

Publication Details

Journal
Pediatric Discovery
Published
2024-09-12
DOI
https://doi.org/10.1002/pdi3.2505
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study

Chengjun Liu, Feng Xu, Shaojun Li, Wei Qiu et al.
Pediatric Discovery
Hemodynamic Monitoring and Therapy
article

Perioperative hemodynamic parameters monitored by three noninvasive technologies in children with congenital heart disease: A prospective study

Chengjun Liu, Feng Xu, Shaojun Li, Wei Qiu, Xiaoyu Xiong
article en

Abstract

This study aims to compare the efficiencies of three noninvasive technologies in monitoring the perioperative hemodynamics of children with congenital heart disease (CHD) including ventricular septal defects with or without atrial septal defects. Three noninvasive technologies included transthoracic echocardiography (TTE), electrical cardiometry (EC), and vasoactive inotropic score (VIS). Parameters included left ventricular ejection fraction (LVEF) and cardiac index (cardiac index monitored by ultrasound, uCI) in TTE, cardiac index (cardiac index monitored by electrical cardiometry, eCI) and systemic vascular resistance index (SVRI) in EC, and VIS. Seventy-four children were eligible. Three types of adverse events (AEs) related to disease activity and prognosis were observed, including cardio-pulmonary resuscitation in five cases (5/74, 6.76%), hypoxic-ischemic brain damage in four cases (4/74, 5.41%) and hemopurification in four cases (4/74, 5.41%). Except for LVEF, eight parameters (VISmax [maximum VIS], VISmea [mean VIS], uCImea [mean uCI], uCImin [minimum uCI], eCImea [mean eCI], eCImin [minimum eCI], SVRImea [mean SVRI], and SVRImin [minimum SVRI]) showed predictive value for any AE (<i>p</i> < 0.05). VISmea, uCImea, and eCImea demonstrated the highest accuracy and linear associations (AUROC > 0.9, <i>p</i> = 0.00). Linear associations also existed between the three groups of parameters and the duration of mechanical ventilation (MV) and the length of stay (LOS) in the intensive care unit (ICU). The duration of MV and the LOS in the ICU increased as VISmea rose, or uCImea and eCImea fell (<i>p</i> < 0.05). LVEF in TTE could not predict any AE (<i>p</i> > 0.05) and not fully reflect the cardiovascular function. Therefore, most parameters obtained in TTE, EC, and VIS can reflect the perioperative hemodynamics of children with CHD, with VISmea, uCImea, and eCImea being most accurate.

Pediatric DiscoveryVol. 3(2)
China International Science and Technology Cooperation (CN), Children's Hospital of Chongqing Medical University (CN), Chongqing Medical University (CN)
Good health and well-being
Openalex Percentile: Top 71%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.