Harmonic measurement and analysis system for characterization of adjustable speed drives

• An experimental harmonic analysis method of adjustable speed drives is proposed. • Evaluates distortion in high harmonic and variable fundamental inverter signals. • Uses power quality meter standards adapted to the characteristics of drive outputs. • Includes new features to measure converter signals not available in commercial meters. • Experimental results measuring harmonic distortion at the output of ASDs are obtained. Variable speed drives, commonly employed for motor speed control, incorporate electronic converters that emit harmonics to both the power grid and the motor-load system. These harmonics can have adverse effects on the motors, necessitating the experimental measurement of their diverse and unpredictable harmonic content. To perform these measurements on the input side of the drives or power grid, commercial quality analyzers are available, but they are not prepared to perform these measurements on the motor-load or output side of the drive. The outputs of the drives generate a significant harmonic and interharmonic content across a wide range of low and high frequencies, coupled with variable fundamental frequencies. Consequently, the development of a specialized measurement system tailored to these signal characteristics becomes imperative. This paper presents a harmonic measurement and analysis system specifically designed for frequency inverter’s output signals, which adheres to international standards that standardize measurements and includes new features to evaluate converter signals not available in commercial meters. By utilizing this system, frequency groupings and distortion rates are obtained to comprehensively analyze the power quality of commercial drives under realistic operating conditions, thus enabling the early detection of potential failures and the implementation of preventive measures.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2024-09-13
DOI
https://doi.org/10.1016/j.ijepes.2024.110217
Citations
6
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
2.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic measurement and analysis system for characterization of adjustable speed drives

Ángel Zorita-Lamadrid, Angel Arranz-Gimon, Vanesa Fernandez-Cavero, Óscar Duque-Pérez et al.
6 citations
International Journal of Electrical Power & Energy Systems
Sensor Technology and Measurement Systems
2.09
article

Harmonic measurement and analysis system for characterization of adjustable speed drives

Ángel Zorita-Lamadrid, Angel Arranz-Gimon, Vanesa Fernandez-Cavero, Óscar Duque-Pérez, Daniel Moríñigo-Sotelo
article en
6 citations

Abstract

• An experimental harmonic analysis method of adjustable speed drives is proposed. • Evaluates distortion in high harmonic and variable fundamental inverter signals. • Uses power quality meter standards adapted to the characteristics of drive outputs. • Includes new features to measure converter signals not available in commercial meters. • Experimental results measuring harmonic distortion at the output of ASDs are obtained. Variable speed drives, commonly employed for motor speed control, incorporate electronic converters that emit harmonics to both the power grid and the motor-load system. These harmonics can have adverse effects on the motors, necessitating the experimental measurement of their diverse and unpredictable harmonic content. To perform these measurements on the input side of the drives or power grid, commercial quality analyzers are available, but they are not prepared to perform these measurements on the motor-load or output side of the drive. The outputs of the drives generate a significant harmonic and interharmonic content across a wide range of low and high frequencies, coupled with variable fundamental frequencies. Consequently, the development of a specialized measurement system tailored to these signal characteristics becomes imperative. This paper presents a harmonic measurement and analysis system specifically designed for frequency inverter’s output signals, which adheres to international standards that standardize measurements and includes new features to evaluate converter signals not available in commercial meters. By utilizing this system, frequency groupings and distortion rates are obtained to comprehensively analyze the power quality of commercial drives under realistic operating conditions, thus enabling the early detection of potential failures and the implementation of preventive measures.

International Journal of Electrical Power & Energy SystemsVol. 162
Universidad de Valladolid (ES), Universidad de Burgos (ES)
Affordable and clean energy
Openalex Percentile: Top 12%
Sensor Technology and Measurement Systems
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.