Visual assessments of 11C-Pittsburgh compound-B PET vs. 18F-flutemetamol PET across the age spectrum

Age, GM/WM binding, amyloid-β load, and disease severity may affect visual assessments of PET ligands. Increase in WM binding with age causes a loss of contrast between GM and WM on 11 C-PiB-PET, particularly in CU younger adults, leading to false positivity. In CU older adults, increased WM signal may bleed more into cortical regions, hiding subtle cortical uptake, especially with 18 F-flutemetamol, whereas 11 C-PiB can detect true regional positivity. Understanding these differences will improve patient care and treatment evaluation in clinic and clinical trials.

Authors

Institutions

Publication Details

Journal
Nuclear Medicine Communications
Published
2024-09-13
DOI
https://doi.org/10.1097/mnm.0000000000001902
Citations
3
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual assessments of 11C-Pittsburgh compound-B PET vs. 18F-flutemetamol PET across the age spectrum

Val J. Lowe, Clifford R. Jack, Derek Richard Johnson, Orhun H. Kantarci et al.
3 citations
Nuclear Medicine Communications
Medical Imaging Techniques and Applications
1.21
article

Visual assessments of 11C-Pittsburgh compound-B PET vs. 18F-flutemetamol PET across the age spectrum

Val J. Lowe, Clifford R. Jack, Derek Richard Johnson, Orhun H. Kantarci, Scott A. Przybelski, Bradley J. Kemp, Burcu Zeydan, Matthew L. Senjem, Timothy G. Lesnick, Christopher G. Schwarz, Kejal Kantarci, Hoon‐Ki Min
article en
3 citations

Abstract

Age, GM/WM binding, amyloid-β load, and disease severity may affect visual assessments of PET ligands. Increase in WM binding with age causes a loss of contrast between GM and WM on 11 C-PiB-PET, particularly in CU younger adults, leading to false positivity. In CU older adults, increased WM signal may bleed more into cortical regions, hiding subtle cortical uptake, especially with 18 F-flutemetamol, whereas 11 C-PiB can detect true regional positivity. Understanding these differences will improve patient care and treatment evaluation in clinic and clinical trials.

Nuclear Medicine CommunicationsVol. 45(12)
Mayo Clinic (US), WinnMed (US)
National Institutes of Health
Good health and well-being
Openalex Percentile: Top 20%
Medical Imaging Techniques and Applications
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual assessments of 11C-Pittsburgh compound-B PET vs. 18F-flutemetamol PET across the age spectrum — Val J. Lowe, Clifford R. Jack, et al. · Nuclear Medicine Communications (2024) | TGRS Research Map | TGRS