A Performance Evaluation of Convolutional Neural Network Architectures for Pterygium Detection in Anterior Segment Eye Images

In this article, various convolutional neural network (CNN) architectures for the detection of pterygium in the anterior segment of the eye are explored and compared. Five CNN architectures (ResNet101, ResNext101, Se-ResNext50, ResNext50, and MobileNet V2) are evaluated with the objective of identifying one that surpasses the precision and diagnostic efficacy of the current existing solutions. The results show that the Se-ResNext50 architecture offers the best overall performance in terms of precision, recall, and accuracy, with values of 93%, 92%, and 92%, respectively, for these metrics. These results demonstrate its potential to enhance diagnostic tools in ophthalmology.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-09-13
DOI
https://doi.org/10.3390/diagnostics14182026
Citations
2
Primary Topic
Corneal Surgery and Treatments
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Performance Evaluation of Convolutional Neural Network Architectures for Pterygium Detection in Anterior Segment Eye Images

Pedro Castañeda, David Mauricio, Edward Jordy Ticlavilca-Inche, Maria Isabel Moreno-Lozano et al.
2 citations
Diagnostics
Corneal Surgery and Treatments
0.81
article

A Performance Evaluation of Convolutional Neural Network Architectures for Pterygium Detection in Anterior Segment Eye Images

Pedro Castañeda, David Mauricio, Edward Jordy Ticlavilca-Inche, Maria Isabel Moreno-Lozano, Sandra Wong-Durand, Alejandra Oñate-Andino
article en
2 citations

Abstract

In this article, various convolutional neural network (CNN) architectures for the detection of pterygium in the anterior segment of the eye are explored and compared. Five CNN architectures (ResNet101, ResNext101, Se-ResNext50, ResNext50, and MobileNet V2) are evaluated with the objective of identifying one that surpasses the precision and diagnostic efficacy of the current existing solutions. The results show that the Se-ResNext50 architecture offers the best overall performance in terms of precision, recall, and accuracy, with values of 93%, 92%, and 92%, respectively, for these metrics. These results demonstrate its potential to enhance diagnostic tools in ophthalmology.

DiagnosticsVol. 14(18)
Peruvian University of Applied Sciences (PE), National University of San Marcos (PE), Escuela Superior Politécnica del Chimborazo (EC)
Industry, innovation and infrastructure
Openalex Percentile: Top 26%
Corneal Surgery and Treatments
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.