Study on Response Time Hysteresis Model of Smoke Detectors in Aircraft Cargo Compartment

A fire in the cargo compartment has a major impact on civil aviation flight safety, and according to the airworthiness clause of the CCAR-25, the detector must sound an alarm within 1 min of a fire in the cargo compartment. As for the cargo compartment of large transport aircrafts, the internal space is high and open, and the smoke movement speed becomes slower with significant cooling in the process of diffusion. Hysteresis can occur in smoke detectors because of their internal labyrinth structure, which causes the detector’s internal and external response signals to be out of sync. This research employs a numerical simulation to examine the detector response parameters under an ambient wind speed of 0.1–0.2 m/s and fits a Cleary two-stage hysteresis model, where τ1= 0.09u−1.43 and τ2= 0.67u−1.59. Finally, multiple full-scale cargo cabin experiments were conducted to validate the prediction model. The results show that the model’s predicted alarm range is 43.1 s to 49.0 s, and the actual alarm time obtained by the experiment falls within this interval, confirming the model’s accuracy and providing theoretical support for the structural design and layout of the aircraft cargo cabin smoke detector.

Authors

Institutions

Publication Details

Journal
Fire
Published
2024-09-13
DOI
https://doi.org/10.3390/fire7090317
Citations
3
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
1.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Response Time Hysteresis Model of Smoke Detectors in Aircraft Cargo Compartment

Hongwei Cui, Shengdong Wang, Minqiang Wang, Song Lu et al.
3 citations
Fire
Fire dynamics and safety research
1.09
article

Study on Response Time Hysteresis Model of Smoke Detectors in Aircraft Cargo Compartment

Hongwei Cui, Shengdong Wang, Minqiang Wang, Song Lu, Heping Zhang, Chenran Ruan
article en
3 citations

Abstract

A fire in the cargo compartment has a major impact on civil aviation flight safety, and according to the airworthiness clause of the CCAR-25, the detector must sound an alarm within 1 min of a fire in the cargo compartment. As for the cargo compartment of large transport aircrafts, the internal space is high and open, and the smoke movement speed becomes slower with significant cooling in the process of diffusion. Hysteresis can occur in smoke detectors because of their internal labyrinth structure, which causes the detector’s internal and external response signals to be out of sync. This research employs a numerical simulation to examine the detector response parameters under an ambient wind speed of 0.1–0.2 m/s and fits a Cleary two-stage hysteresis model, where τ1= 0.09u−1.43 and τ2= 0.67u−1.59. Finally, multiple full-scale cargo cabin experiments were conducted to validate the prediction model. The results show that the model’s predicted alarm range is 43.1 s to 49.0 s, and the actual alarm time obtained by the experiment falls within this interval, confirming the model’s accuracy and providing theoretical support for the structural design and layout of the aircraft cargo cabin smoke detector.

FireVol. 7(9)
University of Science and Technology of China (CN)
National Natural Science Foundation of China, Ministry of Industry and Information Technology of the People's Republic of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 23%
Fire dynamics and safety research
1.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.