EXPERIMENTAL EVALUATION OF THERMAL PERFORMANCE OF A HEAT EXCHANGER USING THERMOSYPHONS

Heat exchangers are devices that aim to improve heat exchange between two fluids at different temperatures, without them mixing. The characteristics that differentiate the types of exchangers are their geometric and constructive shapes, exemplified by the shell and tubes, serpentine, finned, plate, and double tube types, among others. For the present paper, a heat exchanger tube is used, which is connected by thermosyphons to carry out the thermal exchange between the fluids without mixing them. In order to increase the thermal efficiency of the heat exchanger, it is necessary more efficient thermal exchange devices. For this purpose, in this case, we use thermosyphons. The goal of this experimental study is to evaluate the thermal efficiency of the heat exchanger using thermosyphons. In this study, the thermosyphons were manufactured in copper with outer diameter of 9.45mm, an inner diameter of 7.75mm, and a total length of 180mm. The condenser, evaporator, and adiabatic sections all have the same size of 60mm. Three thermosyphons connected the two fluids of the heat exchanger, each one filled with distilled water with a filling ratio of 40% of the evaporator volume and experimentally tested with an angle of 67.5º relative to the horizontal with the surfaces at fixed temperatures (Dirichlet conditions) and the cooling being carried out by convection forced water. The thermal analysis was based on the temperature distribution along the length, the operating temperature, and the thermal resistance. Given the results observed for the thermal resistance, it was possible to find the thermal efficiency of the heat exchanger.

Authors

Institutions

Publication Details

Journal
Revista de Engenharia Térmica
Published
2024-09-12
DOI
https://doi.org/10.5380/reterm.v23i2.96853
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPERIMENTAL EVALUATION OF THERMAL PERFORMANCE OF A HEAT EXCHANGER USING THERMOSYPHONS

Thiago Antonini Alves, Felipe Mercês Biglia, Victor Vaurek Dimbarre, Pedro Leineker Ochoski Machado et al.
Revista de Engenharia Térmica
Heat Transfer and Optimization
article

EXPERIMENTAL EVALUATION OF THERMAL PERFORMANCE OF A HEAT EXCHANGER USING THERMOSYPHONS

Thiago Antonini Alves, Felipe Mercês Biglia, Victor Vaurek Dimbarre, Pedro Leineker Ochoski Machado, A J Vaz, PAULO HENRIQUE DIAS DOS SANTOS
article en

Abstract

Heat exchangers are devices that aim to improve heat exchange between two fluids at different temperatures, without them mixing. The characteristics that differentiate the types of exchangers are their geometric and constructive shapes, exemplified by the shell and tubes, serpentine, finned, plate, and double tube types, among others. For the present paper, a heat exchanger tube is used, which is connected by thermosyphons to carry out the thermal exchange between the fluids without mixing them. In order to increase the thermal efficiency of the heat exchanger, it is necessary more efficient thermal exchange devices. For this purpose, in this case, we use thermosyphons. The goal of this experimental study is to evaluate the thermal efficiency of the heat exchanger using thermosyphons. In this study, the thermosyphons were manufactured in copper with outer diameter of 9.45mm, an inner diameter of 7.75mm, and a total length of 180mm. The condenser, evaporator, and adiabatic sections all have the same size of 60mm. Three thermosyphons connected the two fluids of the heat exchanger, each one filled with distilled water with a filling ratio of 40% of the evaporator volume and experimentally tested with an angle of 67.5º relative to the horizontal with the surfaces at fixed temperatures (Dirichlet conditions) and the cooling being carried out by convection forced water. The thermal analysis was based on the temperature distribution along the length, the operating temperature, and the thermal resistance. Given the results observed for the thermal resistance, it was possible to find the thermal efficiency of the heat exchanger.

Revista de Engenharia TérmicaVol. 23(2)
Federal University of Technology (NG)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Universidade Tecnológica Federal do Paraná
Affordable and clean energy
Openalex Percentile: Top 85%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.