Impact of trapezoidal ribs on the performance of solar air collector: A numerical solution with optimized rib dimensions for better performance

• The impact of trapezoidal ribs over the absorber plate of the solar air collector was investigated. • Dimensions of trapezoidal ribs were proposed based on 108 sets of simulation results. • The output parameters Nusselt number ( Nu ), Nu ratio and thermo-hydraulic performance index were evaluated for all 108 simulations. • The Nu of trapezoidal ribs increased to 2.663 times more than the flat plates. • The proposed dimensions are rib pitch ( p ) = 140 mm, rib height ( e ) = 4 mm and rib angle ( α ) = 38.66°. In the present study, a 2D numerical analysis of the solar air collector (SAC) of an indirect solar dryer having trapezoidal corrugations on the absorber plate was performed. Corrugation pitch, p (twelve values ranged from 20 to 160 mm) and height, e (six values ranged from 1 to 10 mm) were varied and analyzed for six values of Reynolds numbers ( Re ). The output characteristics such as Nusselt number ( Nu ), friction factor ( f ) and thermo-hydraulic performance index ( T hp ) were calculated for different p, e and Re . The total work was categorized into two parts (part-I for optimizing p and part-II for optimizing e ). 18 domains (twelve for part-I and six for part-II simulations) were generated and 108 simulations were executed to find the optimum dimensions ( p, e and corrugation angle, α ) of the corrugation. ANSYS Fluent-v15 was used to solve the problem. The maximum Nu for the corrugated sheet was 2.663 times greater than the flat absorber plate. The maximum T hp range was from 1.435 to 1.699 and obtained at the optimal values of p = 140 mm, e = 4 mm and α = 38.66° The numerical results were compared with the existing literature.

Authors

Institutions

Publication Details

Journal
Cleaner Energy Systems
Published
2024-09-13
DOI
https://doi.org/10.1016/j.cles.2024.100147
Citations
4
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of trapezoidal ribs on the performance of solar air collector: A numerical solution with optimized rib dimensions for better performance

Shekher Sheelam, V. P. Chandramohan, Mosuru Hari Krishna
4 citations
Cleaner Energy Systems
Heat Transfer Mechanisms
0.85
article

Impact of trapezoidal ribs on the performance of solar air collector: A numerical solution with optimized rib dimensions for better performance

Shekher Sheelam, V. P. Chandramohan, Mosuru Hari Krishna
article en
4 citations

Abstract

• The impact of trapezoidal ribs over the absorber plate of the solar air collector was investigated. • Dimensions of trapezoidal ribs were proposed based on 108 sets of simulation results. • The output parameters Nusselt number ( Nu ), Nu ratio and thermo-hydraulic performance index were evaluated for all 108 simulations. • The Nu of trapezoidal ribs increased to 2.663 times more than the flat plates. • The proposed dimensions are rib pitch ( p ) = 140 mm, rib height ( e ) = 4 mm and rib angle ( α ) = 38.66°. In the present study, a 2D numerical analysis of the solar air collector (SAC) of an indirect solar dryer having trapezoidal corrugations on the absorber plate was performed. Corrugation pitch, p (twelve values ranged from 20 to 160 mm) and height, e (six values ranged from 1 to 10 mm) were varied and analyzed for six values of Reynolds numbers ( Re ). The output characteristics such as Nusselt number ( Nu ), friction factor ( f ) and thermo-hydraulic performance index ( T hp ) were calculated for different p, e and Re . The total work was categorized into two parts (part-I for optimizing p and part-II for optimizing e ). 18 domains (twelve for part-I and six for part-II simulations) were generated and 108 simulations were executed to find the optimum dimensions ( p, e and corrugation angle, α ) of the corrugation. ANSYS Fluent-v15 was used to solve the problem. The maximum Nu for the corrugated sheet was 2.663 times greater than the flat absorber plate. The maximum T hp range was from 1.435 to 1.699 and obtained at the optimal values of p = 140 mm, e = 4 mm and α = 38.66° The numerical results were compared with the existing literature.

Cleaner Energy SystemsVol. 9
National Institute of Technology Warangal (IN), Rajiv Gandhi University of Knowledge Technologies (IN)
National Institute of Technology Warangal
Affordable and clean energy
Openalex Percentile: Top 31%
Heat Transfer Mechanisms
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of trapezoidal ribs on the performance of solar air collector: A numerical solution with optimized rib dimensions for better performance — Shekher Sheelam, V. P. Chandramohan, et al. · Cleaner Energy Systems (2024) | TGRS Research Map | TGRS