Investigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations

Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how these materials and structures behave under elevated temperatures is crucial for fire safety. The authors have performed experimental studies previously on GI-based CFS under elevated temperatures. In that study, CFS sections made of GI of grade E350 of 1.5 m long and 2 mm thickness were used. Built-up beam sections were tested under two-point loading after heating to 60 and 90 min durations and subsequently cooling them down using air and water. This study aims to uncover the influence of different stiffener configurations on the load carrying capacity of sections under elevated temperature parametrically. With the experimental study results from previous studies as a reference, authors used FEM analysis to comprehensively study the behavior of GI-based CFS sections under fire. Vertical, horizontal, and not providing a stiffener were the configurations selected to study the beams parametrically. Parametric analysis confirmed that different stiffener configurations did not alter the predominant failure mode, which remained distortional buckling across all specimens. Beams with vertical stiffeners demonstrated superior performance compared to those with horizontal stiffeners in parametric analysis. Lateral–torsional buckling was observed in the reference specimen, lacking stiffeners due to inadequate restraint at the supports.

Authors

Institutions

Publication Details

Journal
Fire
Published
2024-09-13
DOI
https://doi.org/10.3390/fire7090318
Citations
19
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
4.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations

A. Diana Andrushia, G. Beulah Gnana Ananthi, Anand Nammalvar, Varun Sabu Sam et al.
19 citations
Fire
Fire effects on concrete materials
4.96
article

Investigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations

A. Diana Andrushia, G. Beulah Gnana Ananthi, Anand Nammalvar, Varun Sabu Sam, Krishanu Roy, Garry Wegara K Marak
article en
19 citations

Abstract

Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how these materials and structures behave under elevated temperatures is crucial for fire safety. The authors have performed experimental studies previously on GI-based CFS under elevated temperatures. In that study, CFS sections made of GI of grade E350 of 1.5 m long and 2 mm thickness were used. Built-up beam sections were tested under two-point loading after heating to 60 and 90 min durations and subsequently cooling them down using air and water. This study aims to uncover the influence of different stiffener configurations on the load carrying capacity of sections under elevated temperature parametrically. With the experimental study results from previous studies as a reference, authors used FEM analysis to comprehensively study the behavior of GI-based CFS sections under fire. Vertical, horizontal, and not providing a stiffener were the configurations selected to study the beams parametrically. Parametric analysis confirmed that different stiffener configurations did not alter the predominant failure mode, which remained distortional buckling across all specimens. Beams with vertical stiffeners demonstrated superior performance compared to those with horizontal stiffeners in parametric analysis. Lateral–torsional buckling was observed in the reference specimen, lacking stiffeners due to inadequate restraint at the supports.

FireVol. 7(9)
Karunya University (IN), Anna University, Chennai (IN), University of Waikato (NZ)
Openalex Percentile: Top 4%
Fire effects on concrete materials
4.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.