A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector

Affordable, accurate, and robust temporal measurement devices are desirable for screening and assessment of radon levels in private homes and workplaces. This research expands upon prior research, using the RadonFTlab RadonEye device through a comparison of multiple samples of this instrument with a laboratory-grade instrument, the Saphymo AlphaGUARD, over a more extensive period than reported previously. Data were collected over 291 d in a poorly ventilated basement space in an occupied building. Environmental conditions varied naturally, changing both the radon source term and radon entry into the space approximating typically deployed conditions. The R-squared linear regression correlation coefficient and relative sensitivities of each RadonEye with the AlphaGUARD were computed. Overall temporal and diurnal variations were also studied. The sensitivities of all RadonEyes and the AlphaGUARD agreed to within 22% throughout the entire deployment period.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-09-13
DOI
https://doi.org/10.1097/hp.0000000000001858
Citations
2
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector

Kimberlee J. Kearfott, Carly E. Evans
2 citations
Health Physics
Radioactivity and Radon Measurements
0.90
article

A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector

Kimberlee J. Kearfott, Carly E. Evans
article en
2 citations

Abstract

Affordable, accurate, and robust temporal measurement devices are desirable for screening and assessment of radon levels in private homes and workplaces. This research expands upon prior research, using the RadonFTlab RadonEye device through a comparison of multiple samples of this instrument with a laboratory-grade instrument, the Saphymo AlphaGUARD, over a more extensive period than reported previously. Data were collected over 291 d in a poorly ventilated basement space in an occupied building. Environmental conditions varied naturally, changing both the radon source term and radon entry into the space approximating typically deployed conditions. The R-squared linear regression correlation coefficient and relative sensitivities of each RadonEye with the AlphaGUARD were computed. Overall temporal and diurnal variations were also studied. The sensitivities of all RadonEyes and the AlphaGUARD agreed to within 22% throughout the entire deployment period.

Health PhysicsVol. 128(1)
University of Michigan (US)
Openalex Percentile: Top 26%
Radioactivity and Radon Measurements
0.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector — Kimberlee J. Kearfott, Carly E. Evans · Health Physics (2024) | TGRS Research Map | TGRS