Biochemically Programmable Isothermal PCR

Isothermal PCR can be performed by imposing a static temperature gradient that continuously circulates reagents through denaturing, annealing, and extension conditions inside a PCR tube. But despite early promise, these systems have yet to demonstrate performance and repeatability sufficient for adoption in validated laboratory tests because the rate-limiting extension step is inherently short and cannot be increased independently of the other stages in a temperature cycle. Here, a discovery that enables isothermal PCR to be achieved with statistically robust repeatability that meets or exceeds diagnostic assay requirements (false positive/negative rate <8% at 95% confidence) by manipulating the interplay between the DNA replication biochemistry (via the amplicon GC content) and the microscale circulatory flow inside a PCR tube is reported. Surprisingly, optimal performance depends on selecting primer sequences that replicate high GC content amplicons, contradicting established PCR primer design rules. This innovative thermocycling approach accelerates PCR to speeds rivaling ultra-fast instruments, enabling rapid, repeatable isothermal DNA analysis across a range of targets relevant to diagnostics and pathogen detection.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2024-09-13
DOI
https://doi.org/10.1002/advs.202404688
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biochemically Programmable Isothermal PCR

MinGin Kim, Yassin A. Hassan, Victor M. Ugaz, V. Ravisankar
2 citations
Advanced Science
Biosensors and Analytical Detection
0.37
article

Biochemically Programmable Isothermal PCR

MinGin Kim, Yassin A. Hassan, Victor M. Ugaz, V. Ravisankar
article en
2 citations

Abstract

Isothermal PCR can be performed by imposing a static temperature gradient that continuously circulates reagents through denaturing, annealing, and extension conditions inside a PCR tube. But despite early promise, these systems have yet to demonstrate performance and repeatability sufficient for adoption in validated laboratory tests because the rate-limiting extension step is inherently short and cannot be increased independently of the other stages in a temperature cycle. Here, a discovery that enables isothermal PCR to be achieved with statistically robust repeatability that meets or exceeds diagnostic assay requirements (false positive/negative rate <8% at 95% confidence) by manipulating the interplay between the DNA replication biochemistry (via the amplicon GC content) and the microscale circulatory flow inside a PCR tube is reported. Surprisingly, optimal performance depends on selecting primer sequences that replicate high GC content amplicons, contradicting established PCR primer design rules. This innovative thermocycling approach accelerates PCR to speeds rivaling ultra-fast instruments, enabling rapid, repeatable isothermal DNA analysis across a range of targets relevant to diagnostics and pathogen detection.

Advanced ScienceVol. 11(41)
Texas A&M University (US)
National Science Foundation, U.S. Department of Commerce, W. M. Keck Foundation, Directorate for Engineering, National Institute of Standards and Technology, National Institute for Innovation in Manufacturing Biopharmaceuticals
Openalex Percentile: Top 44%
Biosensors and Analytical Detection
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.