Egress Safety for STUDIO Residential Buildings

In recent years, the number of studio residential buildings has increased significantly in Korea, as well as in many other countries, due to changes in living patterns. In Korea especially, there have been many fire accidents in studio residential buildings, which have caused a huge number of casualties and property damages, because the buildings were not adequately equipped for firefighting. In this study, the egress safety of a typical studio residential building in Korea is analyzed. Fire simulations were performed with variables of the fire location and the capacity of the smoke exhaust system to estimate the available safe egress time (ASET); egress simulations were also performed with the variable of egress delay time, and the required safe egress time (RSET) was determined. Then, the egress safety was evaluated, and the criteria for egress safety evaluation were proposed based on the simulation results. A studio residential building with a floor plan different from the prototype was used to validate the proposed egress safety criteria. Finally, a simple evaluation model is presented to estimate the required safe egress time (RSET) without simulation and to examine the impact of bottlenecks.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-13
DOI
https://doi.org/10.3390/buildings14092901
Citations
2
Primary Topic
Occupational Health and Safety Research
Type
article
Field-Weighted Citation Impact
0.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Egress Safety for STUDIO Residential Buildings

Seung‐Ho Choi, Kang Su Kim, Khaliunaa Darkhanbat, Inwook Heo
2 citations
Buildings
Occupational Health and Safety Research
0.90
article

Egress Safety for STUDIO Residential Buildings

Seung‐Ho Choi, Kang Su Kim, Khaliunaa Darkhanbat, Inwook Heo
article en
2 citations

Abstract

In recent years, the number of studio residential buildings has increased significantly in Korea, as well as in many other countries, due to changes in living patterns. In Korea especially, there have been many fire accidents in studio residential buildings, which have caused a huge number of casualties and property damages, because the buildings were not adequately equipped for firefighting. In this study, the egress safety of a typical studio residential building in Korea is analyzed. Fire simulations were performed with variables of the fire location and the capacity of the smoke exhaust system to estimate the available safe egress time (ASET); egress simulations were also performed with the variable of egress delay time, and the required safe egress time (RSET) was determined. Then, the egress safety was evaluated, and the criteria for egress safety evaluation were proposed based on the simulation results. A studio residential building with a floor plan different from the prototype was used to validate the proposed egress safety criteria. Finally, a simple evaluation model is presented to estimate the required safe egress time (RSET) without simulation and to examine the impact of bottlenecks.

BuildingsVol. 14(9)
University of Seoul (KR)
Openalex Percentile: Top 26%
Occupational Health and Safety Research
0.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Egress Safety for STUDIO Residential Buildings — Seung‐Ho Choi, Kang Su Kim, et al. · Buildings (2024) | TGRS Research Map | TGRS