Novel sensitive electrochemical detection of paracetamol using magnetite/MXene electrode by differential pulse voltammetry

In this research work, a novel electrochemical sensor-based Fe 3 O 4 /Ti 3 C 2 MXene @ glassy carbon electrode (GCE) for the detection of paracetamol was prepared by simple ultrasonic method by combining Ti 3 C 2 MXene and Fe 3 O 4 nanoparticles. The Fe 3 O 4 /Ti 3 C 2 MXene nanomaterial was characterized by the means of different techniques: X-ray diffraction (XRD), transmission and scanning electron microscopy (TEM), nitrogen adsorption/desorption isotherms, as well as Fourier transform infrared spectroscopy (FTIR). The characterization results revealed the homogenous distribution of the prepared cubic Fe 3 O 4 NPs within the prepared two-dimensional layered Ti 3 C 2 MXene. The Fe 3 O 4 /Ti 3 C 2 MXene @ GCE was used for the sensitive determination of the well-known analgesic drug paracetamol by differential pulse voltammetry (DPV). The prepared Fe 3 O 4 /Ti 3 C 2 MXene @ GCE was characterized electrochemically, and the results showed that Fe 3 O 4 /Ti 3 C 2 MXene @ GCE is a potential working electrode for the sensitive detection of paracetamol with very low detection limit (0.63 nM), within a linear dynamic range of 0.0–110.0 µM, high reproducibility and repeatability; with a very low relative standard deviation (SD%) for 7 days measurement (3.07–3.42 %), accuracy with a SD% of 0.89, high precision of 99.48 % in distilled water and 98.51 % in sea water. The proposed electroanalytical method was applied for the detection and quantification of paracetamol in real water samples, as well as different analgesic medical formulations, and the results showed outstanding accuracy and precision indicating the suitability of the Fe 3 O 4 /Ti 3 C 2 MXene @ GCE electrode for the sensitive, accurate determination of paracetamol in diferrent matrices. • A novel Fe 3 O 4 @Ti 3 C 2 MXene nanophotocatalyst was prepared by simple ultrasonic method. • Fe 3 O 4 @Ti 3 C 2 MXene nanophotocatalyst was characterized fully. • The sensor-based Fe 3 O 4 /Ti 3 C 2 MXene @ GCE for the detection of paracetamol. • The method showed high reproducibility, repeatability, accuracy, precision, and very low detection limit.

Authors

Publication Details

Journal
International Journal of Electrochemical Science
Published
2024-09-13
DOI
https://doi.org/10.1016/j.ijoes.2024.100797
Citations
6
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
0.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel sensitive electrochemical detection of paracetamol using magnetite/MXene electrode by differential pulse voltammetry

Mohamed Abdel Salam, Éder C. Lima, Ekram Y. Danish, M.A. Gabal et al.
6 citations
International Journal of Electrochemical Science
MXene and MAX Phase Materials
0.70
article

Novel sensitive electrochemical detection of paracetamol using magnetite/MXene electrode by differential pulse voltammetry

Mohamed Abdel Salam, Éder C. Lima, Ekram Y. Danish, M.A. Gabal, Amal M. Alkhudaydi, Basel A. Samy
article en
6 citations

Abstract

In this research work, a novel electrochemical sensor-based Fe 3 O 4 /Ti 3 C 2 MXene @ glassy carbon electrode (GCE) for the detection of paracetamol was prepared by simple ultrasonic method by combining Ti 3 C 2 MXene and Fe 3 O 4 nanoparticles. The Fe 3 O 4 /Ti 3 C 2 MXene nanomaterial was characterized by the means of different techniques: X-ray diffraction (XRD), transmission and scanning electron microscopy (TEM), nitrogen adsorption/desorption isotherms, as well as Fourier transform infrared spectroscopy (FTIR). The characterization results revealed the homogenous distribution of the prepared cubic Fe 3 O 4 NPs within the prepared two-dimensional layered Ti 3 C 2 MXene. The Fe 3 O 4 /Ti 3 C 2 MXene @ GCE was used for the sensitive determination of the well-known analgesic drug paracetamol by differential pulse voltammetry (DPV). The prepared Fe 3 O 4 /Ti 3 C 2 MXene @ GCE was characterized electrochemically, and the results showed that Fe 3 O 4 /Ti 3 C 2 MXene @ GCE is a potential working electrode for the sensitive detection of paracetamol with very low detection limit (0.63 nM), within a linear dynamic range of 0.0–110.0 µM, high reproducibility and repeatability; with a very low relative standard deviation (SD%) for 7 days measurement (3.07–3.42 %), accuracy with a SD% of 0.89, high precision of 99.48 % in distilled water and 98.51 % in sea water. The proposed electroanalytical method was applied for the detection and quantification of paracetamol in real water samples, as well as different analgesic medical formulations, and the results showed outstanding accuracy and precision indicating the suitability of the Fe 3 O 4 /Ti 3 C 2 MXene @ GCE electrode for the sensitive, accurate determination of paracetamol in diferrent matrices. • A novel Fe 3 O 4 @Ti 3 C 2 MXene nanophotocatalyst was prepared by simple ultrasonic method. • Fe 3 O 4 @Ti 3 C 2 MXene nanophotocatalyst was characterized fully. • The sensor-based Fe 3 O 4 /Ti 3 C 2 MXene @ GCE for the detection of paracetamol. • The method showed high reproducibility, repeatability, accuracy, precision, and very low detection limit.

International Journal of Electrochemical ScienceVol. 19(10)
King Abdulaziz University
Affordable and clean energy
Openalex Percentile: Top 30%
MXene and MAX Phase Materials
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.