Influence of articular cartilage sample geometry on mechanical response and properties using finite element simulation

Mechanical testing of articular cartilage yields highly variable results, posing challenges for tissue characterization. Many factors cause variability, one is sample geometry. Using in-situ phase-contrast enhanced synchrotron micro-tomographs of cartilage samples while tested in unconfined compression (stress relaxation) our group found high variability in the mechanical response. Since all samples originated from a single bovine knee, they were assumed to share mechanical properties. Microscale tomography images showed geometric irregularities in samples that were not accounted for in the often assumed intended cylindrical shape. We aimed to determine the influence of sample shape on mechanical response in unconfined compression and how sample geometry affects identified mechanical properties. Using a parametric FE model incorporating geometric irregularities in a Design of Experiments approach, results were analysed with 2-way ANOVA. Furthermore, a material parameter fitting was done with multiple segmented sample-specific finite element models simultaneously to assess the influence of sample geometry on material parameters. Results revealed that the average inclined sample surface (4°) caused a 15 % decrease in reaction forces compared to the intended cylinder. Fitting multiple sample-specific geometries simultaneously altered material parameters between -70 to +159 % compared to the average model. Strikingly, initial fibril stiffness and permeability increased by 137 % and 159 %, while the root-mean-square error of the fit was reduced by ∼2/3 compared to using parameters from a cylindrical shape model. In conclusion, minor variability in sample geometry affects property characterization and can account for some of the inter-sample variability in the mechanical data for cartilage.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2024-09-13
DOI
https://doi.org/10.1016/j.jbiomech.2024.112323
Citations
3
Primary Topic
Osteoarthritis Treatment and Mechanisms
Type
article
Field-Weighted Citation Impact
1.41
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of articular cartilage sample geometry on mechanical response and properties using finite element simulation

Maria Pierantoni, Hector Dejea, Anna Gustafsson, Lorenzo Grassi et al.
3 citations
Journal of Biomechanics
Osteoarthritis Treatment and Mechanisms
1.41
article

Influence of articular cartilage sample geometry on mechanical response and properties using finite element simulation

Maria Pierantoni, Hector Dejea, Anna Gustafsson, Lorenzo Grassi, Hanna Isaksson, Gustavo A. Orozco, Viktor Jönsson
article en
3 citations

Abstract

Mechanical testing of articular cartilage yields highly variable results, posing challenges for tissue characterization. Many factors cause variability, one is sample geometry. Using in-situ phase-contrast enhanced synchrotron micro-tomographs of cartilage samples while tested in unconfined compression (stress relaxation) our group found high variability in the mechanical response. Since all samples originated from a single bovine knee, they were assumed to share mechanical properties. Microscale tomography images showed geometric irregularities in samples that were not accounted for in the often assumed intended cylindrical shape. We aimed to determine the influence of sample shape on mechanical response in unconfined compression and how sample geometry affects identified mechanical properties. Using a parametric FE model incorporating geometric irregularities in a Design of Experiments approach, results were analysed with 2-way ANOVA. Furthermore, a material parameter fitting was done with multiple segmented sample-specific finite element models simultaneously to assess the influence of sample geometry on material parameters. Results revealed that the average inclined sample surface (4°) caused a 15 % decrease in reaction forces compared to the intended cylinder. Fitting multiple sample-specific geometries simultaneously altered material parameters between -70 to +159 % compared to the average model. Strikingly, initial fibril stiffness and permeability increased by 137 % and 159 %, while the root-mean-square error of the fit was reduced by ∼2/3 compared to using parameters from a cylindrical shape model. In conclusion, minor variability in sample geometry affects property characterization and can account for some of the inter-sample variability in the mechanical data for cartilage.

Journal of BiomechanicsVol. 176
Lund University (SE), MAX IV Laboratory (SE)
Openalex Percentile: Top 18%
Osteoarthritis Treatment and Mechanisms
1.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.