Surface Partial Discharge Characteristics Under Repeated Positive Triangular High Voltages (1 kV/s)

In DC insulation systems, surface partial discharge activity is of major concern, in addition to the normal operating conditions, under transient stress conditions relating to energization and de-energization, voltage polarity reversal, and overvoltage surges. In this study, surface partial discharges in a short sphere-plane gap bridged by polymeric insulating surfaces are investigated under positive triangular high voltages. Discharge modes and their salient characteristics as affected by the applied electric field and insulating material are evaluated and discussed based on current measurements. Emphasis is further given to assess the dependence of surface partial discharge activity on the rise and fall of the applied voltage, repeated testing as well as upon surface charging. Surface discharges are initiated in pulse mode at significantly lower voltages than that observed in air alone; however, the stable glow discharge is established and maintained at markedly higher voltages although related to lower continuous current with greater fluctuation, especially for insulating materials with lower relative permittivity. These are attributed to space and surface charges associated with preceding discharges.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2024-09-13
DOI
https://doi.org/10.1109/tdei.2024.3460735
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Partial Discharge Characteristics Under Repeated Positive Triangular High Voltages (1 kV/s)

Pantelis N. Mikropoulos, Pavlos K. Samaras
IEEE Transactions on Dielectrics and Electrical Insulation
High voltage insulation and dielectric phenomena
article

Surface Partial Discharge Characteristics Under Repeated Positive Triangular High Voltages (1 kV/s)

Pantelis N. Mikropoulos, Pavlos K. Samaras
article en

Abstract

In DC insulation systems, surface partial discharge activity is of major concern, in addition to the normal operating conditions, under transient stress conditions relating to energization and de-energization, voltage polarity reversal, and overvoltage surges. In this study, surface partial discharges in a short sphere-plane gap bridged by polymeric insulating surfaces are investigated under positive triangular high voltages. Discharge modes and their salient characteristics as affected by the applied electric field and insulating material are evaluated and discussed based on current measurements. Emphasis is further given to assess the dependence of surface partial discharge activity on the rise and fall of the applied voltage, repeated testing as well as upon surface charging. Surface discharges are initiated in pulse mode at significantly lower voltages than that observed in air alone; however, the stable glow discharge is established and maintained at markedly higher voltages although related to lower continuous current with greater fluctuation, especially for insulating materials with lower relative permittivity. These are attributed to space and surface charges associated with preceding discharges.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 32(2)
Aristotle University of Thessaloniki (GR)
Affordable and clean energy
Openalex Percentile: Top 91%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.