Technological concepts for broad- and narrow-band absorbers in uncooled thermal imagers visualizing MWIR and LWIR

In the field of microbolometer technology, there are two concepts for tuning the absorption to the desired spectral range. Absorbers based on a λ/4 resonator, which is the standard design for commercial uncooled IR imagers, and Plasmonic Metamaterial Absorbers (PMAs). This paper provides an overview of the optical results of both Fraunhofer IMS’s concepts and a comparison between the two technological approaches in terms of their targeted spectral ranges and bandwidths. We show that the quarter-wavelength resonator-based microbolometers provide a broadband absorption spectrum and the PMA-based microbolometers can have a narrow-band absorption spectrum with a bandwidth of about 0.5 μm. In addition, we show how λ/4 absorbers are primarily suited to thermography, while the PMAs can provide a promising platform for gas cameras.

Authors

Institutions

Publication Details

Published
2024-09-13
DOI
https://doi.org/10.1117/12.3031493
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Technological concepts for broad- and narrow-band absorbers in uncooled thermal imagers visualizing MWIR and LWIR

Marvin Michel, Sebastian Blaeser, Elahe Zakizade, Dirk Weiler et al.
Calibration and Measurement Techniques
article

Technological concepts for broad- and narrow-band absorbers in uncooled thermal imagers visualizing MWIR and LWIR

Marvin Michel, Sebastian Blaeser, Elahe Zakizade, Dirk Weiler, Sascha Weyers, Alexander Litke
article en

Abstract

In the field of microbolometer technology, there are two concepts for tuning the absorption to the desired spectral range. Absorbers based on a λ/4 resonator, which is the standard design for commercial uncooled IR imagers, and Plasmonic Metamaterial Absorbers (PMAs). This paper provides an overview of the optical results of both Fraunhofer IMS’s concepts and a comparison between the two technological approaches in terms of their targeted spectral ranges and bandwidths. We show that the quarter-wavelength resonator-based microbolometers provide a broadband absorption spectrum and the PMA-based microbolometers can have a narrow-band absorption spectrum with a bandwidth of about 0.5 μm. In addition, we show how λ/4 absorbers are primarily suited to thermography, while the PMAs can provide a promising platform for gas cameras.

Fraunhofer Institute for Microelectronic Circuits and Systems (DE)
Affordable and clean energy
Openalex Percentile: Top 77%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.