Calibration of the rotary scale of the primary standard for position angle

A calibration of primary standard rotary scale was carried out based on the establishment of new calibration system. The angle metrological performance including index error, interpolation error, repeatability, and resolution were calibrated separately by comparison with optical polygon and accompanying-calibration angle encoder. The methods of crosscalibration and self-calibration were applied to make the calibration results traceable to circle-closure. The calibration results reveal that the index error is within ±0.04", the interpolation error is within ±0.076", the repeatability is better than 0.005", and the resolution is better than 0.002", which meet NIM's recent requirement of metrological performance for the reproduction of position angle at primary level.

Authors

Institutions

Publication Details

Published
2024-09-13
DOI
https://doi.org/10.1117/12.3032714
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of the rotary scale of the primary standard for position angle

Yuling Gu, Weibin Zhu, Zi Xue, Yao Huang et al.
Advanced Measurement and Metrology Techniques
article

Calibration of the rotary scale of the primary standard for position angle

Yuling Gu, Weibin Zhu, Zi Xue, Yao Huang, Meiliang Xiao, Yi Fang, Dian Zou, Yong‐Sheng Shi, Yu Yang
article en

Abstract

A calibration of primary standard rotary scale was carried out based on the establishment of new calibration system. The angle metrological performance including index error, interpolation error, repeatability, and resolution were calibrated separately by comparison with optical polygon and accompanying-calibration angle encoder. The methods of crosscalibration and self-calibration were applied to make the calibration results traceable to circle-closure. The calibration results reveal that the index error is within ±0.04", the interpolation error is within ±0.076", the repeatability is better than 0.005", and the resolution is better than 0.002", which meet NIM's recent requirement of metrological performance for the reproduction of position angle at primary level.

China Jiliang University (CN), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 85%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibration of the rotary scale of the primary standard for position angle — Yuling Gu, Weibin Zhu, et al. · (2024) | TGRS Research Map | TGRS