Validation of prediction capability of operating space for plasma initiation in MAST-U

Abstract DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mi>loop</mml:mi> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> . In the experimental operating space of p 0 and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mi>loop</mml:mi> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mi>loop</mml:mi> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

Authors

Institutions

Publication Details

Journal
Nuclear Fusion
Published
2024-09-13
DOI
https://doi.org/10.1088/1741-4326/ad7a8c
Citations
5
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
3.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of prediction capability of operating space for plasma initiation in MAST-U

S. Henderson, G. Cunningham, G. Falchetto, Runze Chen et al.
5 citations
Nuclear Fusion
Magnetic confinement fusion research
3.30
article

Validation of prediction capability of operating space for plasma initiation in MAST-U

S. Henderson, G. Cunningham, G. Falchetto, Runze Chen, X. Litaudon, J. Harrison, R. Scannell, A. Thornton, L. A. Kogan, Hana El-Haroun, F. J. Casson, S. Elmore, J. Lovell, Yeongsun Lee, C.H. Vincent, Jeongwon Lee, Hyuntae Kim, Hong Sik Yun, Fabien Jualmes
article en
5 citations

Abstract

Abstract DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mi>loop</mml:mi> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> . In the experimental operating space of p 0 and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mi>loop</mml:mi> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msub> <mml:mi>V</mml:mi> <mml:mrow> <mml:mrow> <mml:mi>loop</mml:mi> </mml:mrow> </mml:mrow> </mml:msub> </mml:mrow> </mml:math> is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

Nuclear FusionVol. 64(12)
Seoul National University (KR), Chinese Academy of Sciences (CN), Czech Academy of Sciences (CZ), Culham Centre for Fusion Energy (GB), CEA Cadarache (FR), United Kingdom Atomic Energy Authority (GB)
Euratom Research and Training Programme, Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 6%
Magnetic confinement fusion research
3.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.