Enhancing P-wave localization for accurate detection of second-degree and third-degree atrioventricular conduction blocks

<i>Objective.</i>This paper tackles the challenge of accurately detecting second-degree and third-degree atrioventricular block (AVB) in electrocardiogram (ECG) signals through automated algorithms. The inaccurate detection of P-waves poses a difficulty in this process. To address this limitation, we propose a reliable method that significantly improves the performances of AVB detection by precisely localizing P-waves.<i>Approach.</i>Our proposed P-WaveNet utilized an attention mechanism to extract spatial and temporal features, and employs a bidirectional long short-term memory module to capture inter-temporal dependencies within the ECG signal. To overcome the scarcity of data for second-degree and third-degree AVB (2AVB,3AVB), a mathematical approach was employed to synthesize pseudo-data. By combining P-wave positions identified by the P-WaveNet with key medical features such as RR interval rhythm and PR intervals, we established a classification rule enabling automatic AVB detection.<i>Main results</i>. The P-WaveNet achieved an F1 score of 93.62% and 91.42% for P-wave localization on the QT Dataset and Lobachevsky University dataset datasets, respectively. In the BUTPDB dataset, the F1 scores for P-wave localization in ECG signals with 2AVB and 3AVB were 98.29% and 62.65%, respectively. Across two independent datasets, the AVB detection algorithm achieved F1 scores of 83.33% and 84.15% for 2AVB and 3AVB, respectively.<i>Significance.</i>Our proposed P-WaveNet demonstrates accurate identification of P-waves in complex ECGs, significantly enhancing AVB detection efficacy. This paper's contributions stem from the fusion of medical expertise with data augmentation techniques and ECG classification. The proposed P-WaveNet demonstrates potential clinical applicability.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2024-09-01
DOI
https://doi.org/10.1088/1361-6579/ad7ad4
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing P-wave localization for accurate detection of second-degree and third-degree atrioventricular conduction blocks

Wenjie Cai, Wenjing Liu, Ming-Jie Wang, Yan Li et al.
Physiological Measurement
ECG Monitoring and Analysis
article

Enhancing P-wave localization for accurate detection of second-degree and third-degree atrioventricular conduction blocks

Wenjie Cai, Wenjing Liu, Ming-Jie Wang, Yan Li, Ziyi Yin, Yangcheng Huang
article en

Abstract

<i>Objective.</i>This paper tackles the challenge of accurately detecting second-degree and third-degree atrioventricular block (AVB) in electrocardiogram (ECG) signals through automated algorithms. The inaccurate detection of P-waves poses a difficulty in this process. To address this limitation, we propose a reliable method that significantly improves the performances of AVB detection by precisely localizing P-waves.<i>Approach.</i>Our proposed P-WaveNet utilized an attention mechanism to extract spatial and temporal features, and employs a bidirectional long short-term memory module to capture inter-temporal dependencies within the ECG signal. To overcome the scarcity of data for second-degree and third-degree AVB (2AVB,3AVB), a mathematical approach was employed to synthesize pseudo-data. By combining P-wave positions identified by the P-WaveNet with key medical features such as RR interval rhythm and PR intervals, we established a classification rule enabling automatic AVB detection.<i>Main results</i>. The P-WaveNet achieved an F1 score of 93.62% and 91.42% for P-wave localization on the QT Dataset and Lobachevsky University dataset datasets, respectively. In the BUTPDB dataset, the F1 scores for P-wave localization in ECG signals with 2AVB and 3AVB were 98.29% and 62.65%, respectively. Across two independent datasets, the AVB detection algorithm achieved F1 scores of 83.33% and 84.15% for 2AVB and 3AVB, respectively.<i>Significance.</i>Our proposed P-WaveNet demonstrates accurate identification of P-waves in complex ECGs, significantly enhancing AVB detection efficacy. This paper's contributions stem from the fusion of medical expertise with data augmentation techniques and ECG classification. The proposed P-WaveNet demonstrates potential clinical applicability.

Physiological MeasurementVol. 45(9)
Shanghai Medical College of Fudan University (CN), University of Shanghai for Science and Technology (CN), Second Military Medical University (CN), Fudan University (CN), Shanghai Pudong New Area Gongli Hospital (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 73%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.