A low-voltage-driven MEMS ultrasonic phased-array transducer for fast 3D volumetric imaging

Abstract Wearable ultrasound imaging technology has become an emerging modality for the continuous monitoring of deep-tissue physiology, providing crucial health and disease information. Fast volumetric imaging that can provide a full spatiotemporal view of intrinsic 3D targets is desirable for interpreting internal organ dynamics. However, existing 1D ultrasound transducer arrays provide 2D images, making it challenging to overcome the trade-off between the temporal resolution and volumetric coverage. In addition, the high driving voltage limits their implementation in wearable settings. With the use of microelectromechanical system (MEMS) technology, we report an ultrasonic phased-array transducer, i.e., a 2D piezoelectric micromachined ultrasound transducer (pMUT) array, which is driven by a low voltage and is chip-compatible for fast 3D volumetric imaging. By grouping multiple pMUT cells into one single drive channel/element, we propose an innovative cell–element–array design and operation of a pMUT array that can be used to quantitatively characterize the key coupling effects between each pMUT cell, allowing 3D imaging with 5-V actuation. The pMUT array demonstrates fast volumetric imaging covering a range of 40 mm × 40 mm × 70 mm in wire phantom and vascular phantom experiments, achieving a high temporal frame rate of 11 kHz. The proposed solution offers a full volumetric view of deep-tissue disorders in a fast manner, paving the way for long-term wearable imaging technology for various organs in deep tissues.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2024-09-12
DOI
https://doi.org/10.1038/s41378-024-00755-9
Citations
15
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
6.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A low-voltage-driven MEMS ultrasonic phased-array transducer for fast 3D volumetric imaging

Hang Gao, Tong Jin, Yun Zhang, Xinchao Lu et al.
15 citations
Microsystems & Nanoengineering
Ultrasound Imaging and Elastography
6.06
article

A low-voltage-driven MEMS ultrasonic phased-array transducer for fast 3D volumetric imaging

Hang Gao, Tong Jin, Yun Zhang, Xinchao Lu, Chengjun Huang, Jianwen Luo, Rui Wang, Qiong He, Zijie Zhao, Chenfang Yan, Tao Wu, Jiawei Li, Kang Du, Yining Deng, Hao Zhang
article en
15 citations

Abstract

Abstract Wearable ultrasound imaging technology has become an emerging modality for the continuous monitoring of deep-tissue physiology, providing crucial health and disease information. Fast volumetric imaging that can provide a full spatiotemporal view of intrinsic 3D targets is desirable for interpreting internal organ dynamics. However, existing 1D ultrasound transducer arrays provide 2D images, making it challenging to overcome the trade-off between the temporal resolution and volumetric coverage. In addition, the high driving voltage limits their implementation in wearable settings. With the use of microelectromechanical system (MEMS) technology, we report an ultrasonic phased-array transducer, i.e., a 2D piezoelectric micromachined ultrasound transducer (pMUT) array, which is driven by a low voltage and is chip-compatible for fast 3D volumetric imaging. By grouping multiple pMUT cells into one single drive channel/element, we propose an innovative cell–element–array design and operation of a pMUT array that can be used to quantitatively characterize the key coupling effects between each pMUT cell, allowing 3D imaging with 5-V actuation. The pMUT array demonstrates fast volumetric imaging covering a range of 40 mm × 40 mm × 70 mm in wire phantom and vascular phantom experiments, achieving a high temporal frame rate of 11 kHz. The proposed solution offers a full volumetric view of deep-tissue disorders in a fast manner, paving the way for long-term wearable imaging technology for various organs in deep tissues.

Microsystems & NanoengineeringVol. 10(1)
Chinese Academy of Sciences (CN), ShanghaiTech University (CN), Institute of Microelectronics (SG), Institute of Microelectronics (CN), University of Chinese Academy of Sciences (CN), Tsinghua University (CN)
Commonwealth Scientific and Industrial Research Organisation, National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 3%
Ultrasound Imaging and Elastography
6.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.