Effect of Impact Energy on the Interface Microstructure of Explosively Clad Mild Steel and Titanium

Abstract Effect of load ratio ( R ) on the interface microstructure and phase stability was investigated in mild steel/Grade-2 Ti explosive clads using experimental and JMatPro® computations. At low-impact-energy conditions (i.e., R = 1.07), the interface exhibited a symmetrical wavy morphology with molten metal entrapped in isolated regions within the vortices of the waves, while at high-impact loading conditions ( R = 3) the interface had complex weld solidification structure consisting of planar interface, columnar and equiaxed dendrites. Based on the study, it was concluded that under high-impact loading conditions, the interface microstructure of the explosive clads will resemble fusion welded joints, but with relatively lower thickness of the interaction zones.

Authors

Institutions

Publication Details

Journal
Transactions of the Indian Institute of Metals
Published
2024-09-12
DOI
https://doi.org/10.1007/s12666-024-03449-y
Citations
1
Primary Topic
High-Velocity Impact and Material Behavior
Type
article
Field-Weighted Citation Impact
0.12

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Impact Energy on the Interface Microstructure of Explosively Clad Mild Steel and Titanium

T. N. Prasanthi, Ravikirana, Pradyumna Kumar Parida, C. Sudha et al.
1 citations
Transactions of the Indian Institute of Metals
High-Velocity Impact and Material Behavior
0.12
article

Effect of Impact Energy on the Interface Microstructure of Explosively Clad Mild Steel and Titanium

T. N. Prasanthi, Ravikirana, Pradyumna Kumar Parida, C. Sudha, R. Mythili
article en
1 citations

Abstract

Abstract Effect of load ratio ( R ) on the interface microstructure and phase stability was investigated in mild steel/Grade-2 Ti explosive clads using experimental and JMatPro® computations. At low-impact-energy conditions (i.e., R = 1.07), the interface exhibited a symmetrical wavy morphology with molten metal entrapped in isolated regions within the vortices of the waves, while at high-impact loading conditions ( R = 3) the interface had complex weld solidification structure consisting of planar interface, columnar and equiaxed dendrites. Based on the study, it was concluded that under high-impact loading conditions, the interface microstructure of the explosive clads will resemble fusion welded joints, but with relatively lower thickness of the interaction zones.

Transactions of the Indian Institute of MetalsVol. 77(11)
SRM Institute of Science and Technology (IN), Homi Bhabha National Institute (IN), Indira Gandhi Centre for Atomic Research (IN)
Indira Gandhi Centre for Atomic Research
Openalex Percentile: Top 60%
High-Velocity Impact and Material Behavior
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Impact Energy on the Interface Microstructure of Explosively Clad Mild Steel and Titanium — T. N. Prasanthi, Ravikirana, et al. · Transactions of the Indian Institute of Metals (2024) | TGRS Research Map | TGRS