Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications

Auto-cascade refrigeration systems are the most employed systems for ultra-low temperature applications, especially for small capacity systems. Recent investigations have allowed to analyze them energetically and thermodynamically, starting a research line focused on enhancing their energy performance from experimental approaches. This work focuses on the energy optimization of a real auto-cascade system working with the mixture R600a/R1150 [70/30 %], which has been evaluated using two compressor models for R404A and R290 as well as the optimization of the two capillary tubes used in the system. Results indicate that overall efficiency of the R290 compressor is up to 21 % higher than with R404A, leading to COP increments between 35 and 81 %. Optimum capillary lengths have been determined in terms of COP and energy consumption, reaching similar values, however, the inner parameters of the system change as function of these lengths, which needs to be considered in prototypes design.

Authors

Publication Details

Journal
Results in Engineering
Published
2024-09-12
DOI
https://doi.org/10.1016/j.rineng.2024.102881
Citations
11
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
2.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications

Manel Martínez-Ángeles, Rodrigo Llopis, Laura Nebot‐Andrés, Daniel Calleja-Anta
11 citations
Results in Engineering
Refrigeration and Air Conditioning Technologies
2.34
article

Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications

Manel Martínez-Ángeles, Rodrigo Llopis, Laura Nebot‐Andrés, Daniel Calleja-Anta
article en
11 citations

Abstract

Auto-cascade refrigeration systems are the most employed systems for ultra-low temperature applications, especially for small capacity systems. Recent investigations have allowed to analyze them energetically and thermodynamically, starting a research line focused on enhancing their energy performance from experimental approaches. This work focuses on the energy optimization of a real auto-cascade system working with the mixture R600a/R1150 [70/30 %], which has been evaluated using two compressor models for R404A and R290 as well as the optimization of the two capillary tubes used in the system. Results indicate that overall efficiency of the R290 compressor is up to 21 % higher than with R404A, leading to COP increments between 35 and 81 %. Optimum capillary lengths have been determined in terms of COP and energy consumption, reaching similar values, however, the inner parameters of the system change as function of these lengths, which needs to be considered in prototypes design.

Results in EngineeringVol. 24
Affordable and clean energy
Openalex Percentile: Top 12%
Refrigeration and Air Conditioning Technologies
2.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental optimization and evaluation of an R600a/R1150 auto-cascade refrigeration systems for ultra-low temperature applications — Manel Martínez-Ángeles, Rodrigo Llopis, et al. · Results in Engineering (2024) | TGRS Research Map | TGRS