Determination of Flash Points of Flammable Mixtures for Explosion Protection

The flash point is the temperature at which the surface of a flammable liquid already produces enough vapour to burst under the influence of an ignition source, such as a spark. When determining the explosion hazard areas of a technology, if it is a combustible liquid, this value is used to determine the fire hazard class according to the current BM Decree 54/2014 (XII. 5.) in Hungary. Also for storage tanks, if flammable liquids are stored, a fire hazard class is determined according to MSZ 9790:1985, which is also based on the flash point of the flammable liquid. It is true worldwide that, for flammable liquids, the flash point data is the basis for determining whether or not there is a risk of explosive vapour under normal operating conditions. In principle, there are two types of flash points, open-cup and close-cup, which should be determined according to EN ISO 13736:2021/A1:2023, EN ISO 2719:2016/A1:2021, ASTM D93:2020, IP 34:2021, ASTM D92:2018, EN ISO 2592:2018, IP 36:2002. For a completely homogeneous liquid, the situation is straightforward because the flash point has already been determined and is treated uniformly in the literature, despite small variations. However, in the case of an inhomogeneous medium containing all percentages of combustible liquid and, for example, water, the flash point will be higher than the value determined for a completely pure combustible liquid. But how much higher? The testing methods described in the standard may not be quickly and easily available to everyone. Based on the current literature, it is possible to determine the flash point of the mixture using a relatively small number of input parameters (Antoine constant, vapour-liquid equilibrium) as a good approximation. The aim of this paper is to describe this relationship by presenting the flash points of ethanol-water and methanol-water mixtures. This is important because if the flash point of a mixture is no longer within the range of explosion protection measures required by regulation or standard, there is no safety justification for the installation and use of explosion-proof designs and additional operational benefits in the EHS area.

Authors

Institutions

Publication Details

Journal
Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomena
Published
2024-09-12
DOI
https://doi.org/10.4028/p-tky3si
Citations
2
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
2.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Flash Points of Flammable Mixtures for Explosion Protection

Zoltán Siménfalvi, Levente Tugyi, G. Szepesi
2 citations
Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomena
Combustion and Detonation Processes
2.60
article

Determination of Flash Points of Flammable Mixtures for Explosion Protection

Zoltán Siménfalvi, Levente Tugyi, G. Szepesi
article en
2 citations

Abstract

The flash point is the temperature at which the surface of a flammable liquid already produces enough vapour to burst under the influence of an ignition source, such as a spark. When determining the explosion hazard areas of a technology, if it is a combustible liquid, this value is used to determine the fire hazard class according to the current BM Decree 54/2014 (XII. 5.) in Hungary. Also for storage tanks, if flammable liquids are stored, a fire hazard class is determined according to MSZ 9790:1985, which is also based on the flash point of the flammable liquid. It is true worldwide that, for flammable liquids, the flash point data is the basis for determining whether or not there is a risk of explosive vapour under normal operating conditions. In principle, there are two types of flash points, open-cup and close-cup, which should be determined according to EN ISO 13736:2021/A1:2023, EN ISO 2719:2016/A1:2021, ASTM D93:2020, IP 34:2021, ASTM D92:2018, EN ISO 2592:2018, IP 36:2002. For a completely homogeneous liquid, the situation is straightforward because the flash point has already been determined and is treated uniformly in the literature, despite small variations. However, in the case of an inhomogeneous medium containing all percentages of combustible liquid and, for example, water, the flash point will be higher than the value determined for a completely pure combustible liquid. But how much higher? The testing methods described in the standard may not be quickly and easily available to everyone. Based on the current literature, it is possible to determine the flash point of the mixture using a relatively small number of input parameters (Antoine constant, vapour-liquid equilibrium) as a good approximation. The aim of this paper is to describe this relationship by presenting the flash points of ethanol-water and methanol-water mixtures. This is important because if the flash point of a mixture is no longer within the range of explosion protection measures required by regulation or standard, there is no safety justification for the installation and use of explosion-proof designs and additional operational benefits in the EHS area.

Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomenaVol. 363
University of Miskolc (HU)
Openalex Percentile: Top 8%
Combustion and Detonation Processes
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.