COMPARISON OF FREEWAY SPACE DISTANCE OF WILLIS METHOD WITH DIGITAL PHOTO ANALYSIS METHOD IN BANJAR TRIBE

Background: The face's vertical dimension or vertical height is the distance between two anatomical points, namely the points on the maxilla and mandible. In measuring the vertical dimension, vertical dimensions of rest (DVR) and vertical dimensions of occlusion (DVO) must be measured. The difference between the vertical dimension of rest (DVR) and the vertical dimension of occlusion (DVO) is called the freeway space (FWS) or interocclusal distance. Freeway space is a key requirement for optimal comfort and function of a partial or complete denture. Each individual's freeway space distance is the movement of muscle function, which can be measured by direct methods such as the Willis method using calipers and the digital photo analysis method using computer software. Two measurement methods can be used to measure freeway space distance direct and indirect. Purpose: To analyze the difference between freeway space distance measured by the Willis method and by digital photo analysis of Adobe Photoshop and Corel Draw graphic design software in the Banjar tribe (a review of students at the Faculty of Dentistry, Universitas Lambung Mangkurat Banjarmasin). Methods: This study is a quantitative study with an analytic observational method and a cross-sectional approach. This study was conducted by collecting data simultaneously at one time by comparing three different methods on the same sample without being given any treatment. Results: One Way ANOVA test is 0.296 (P>0.05) which means there is no significant difference. Conclusion: There is no significant difference between the results of measuring freeway space distance using the Willis method with a digital caliper and digital photo analysis with Adobe Photoshop and Corel Draw software.

Authors

Publication Details

Journal
Dentino Jurnal Kedokteran Gigi
Published
2024-09-02
DOI
https://doi.org/10.20527/dentino.v9i2.20394
Primary Topic
Urban Transport Systems Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARISON OF FREEWAY SPACE DISTANCE OF WILLIS METHOD WITH DIGITAL PHOTO ANALYSIS METHOD IN BANJAR TRIBE

Rahmad Arifin, Diana Wibowo, Dewi Puspitasari, Fachriani Fachriani et al.
Dentino Jurnal Kedokteran Gigi
Urban Transport Systems Analysis
article

COMPARISON OF FREEWAY SPACE DISTANCE OF WILLIS METHOD WITH DIGITAL PHOTO ANALYSIS METHOD IN BANJAR TRIBE

Rahmad Arifin, Diana Wibowo, Dewi Puspitasari, Fachriani Fachriani, I Wayan Arya Krishnawan Firdaus
article en

Abstract

Background: The face's vertical dimension or vertical height is the distance between two anatomical points, namely the points on the maxilla and mandible. In measuring the vertical dimension, vertical dimensions of rest (DVR) and vertical dimensions of occlusion (DVO) must be measured. The difference between the vertical dimension of rest (DVR) and the vertical dimension of occlusion (DVO) is called the freeway space (FWS) or interocclusal distance. Freeway space is a key requirement for optimal comfort and function of a partial or complete denture. Each individual's freeway space distance is the movement of muscle function, which can be measured by direct methods such as the Willis method using calipers and the digital photo analysis method using computer software. Two measurement methods can be used to measure freeway space distance direct and indirect. Purpose: To analyze the difference between freeway space distance measured by the Willis method and by digital photo analysis of Adobe Photoshop and Corel Draw graphic design software in the Banjar tribe (a review of students at the Faculty of Dentistry, Universitas Lambung Mangkurat Banjarmasin). Methods: This study is a quantitative study with an analytic observational method and a cross-sectional approach. This study was conducted by collecting data simultaneously at one time by comparing three different methods on the same sample without being given any treatment. Results: One Way ANOVA test is 0.296 (P>0.05) which means there is no significant difference. Conclusion: There is no significant difference between the results of measuring freeway space distance using the Willis method with a digital caliper and digital photo analysis with Adobe Photoshop and Corel Draw software.

Dentino Jurnal Kedokteran GigiVol. 9(2)
Openalex Percentile: Top 82%
Urban Transport Systems Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.