Use of Molecular Logic Gates for the Tuning of Chemosensor Dynamic Range

Dynamic range is a crucial aspect in the development of fluorescent chemosensors. We aimed to address this issue using molecular logic gates. By creating an AND logic gate with two binding sites for the same type of ion, we increased the dynamic range of a sodium chemosensor while still using the same ionophore. Naphthalimide derivatives <b>1</b> and <b>2</b> were synthesized to test the plausibility of this application. Being an AND logic gate, the second molecule requires two Na<sup>+</sup> ions, while molecule <b>1</b> requires a single ion for sensing. The application of this molecular logic gate is a useful method of altering the chemosensor range.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2024-09-12
DOI
https://doi.org/10.3390/molecules29184330
Citations
3
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Molecular Logic Gates for the Tuning of Chemosensor Dynamic Range

Christopher J. Abelt, Orhan Acikgoz
3 citations
Molecules
Molecular Sensors and Ion Detection
0.72
article

Use of Molecular Logic Gates for the Tuning of Chemosensor Dynamic Range

Christopher J. Abelt, Orhan Acikgoz
article en
3 citations

Abstract

Dynamic range is a crucial aspect in the development of fluorescent chemosensors. We aimed to address this issue using molecular logic gates. By creating an AND logic gate with two binding sites for the same type of ion, we increased the dynamic range of a sodium chemosensor while still using the same ionophore. Naphthalimide derivatives <b>1</b> and <b>2</b> were synthesized to test the plausibility of this application. Being an AND logic gate, the second molecule requires two Na<sup>+</sup> ions, while molecule <b>1</b> requires a single ion for sensing. The application of this molecular logic gate is a useful method of altering the chemosensor range.

MoleculesVol. 29(18)
William & Mary (US), Williams (United States) (US)
Openalex Percentile: Top 33%
Molecular Sensors and Ion Detection
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.