Fast, Simple, and Sensitive Voltammetric Measurements of Acyclovir in Real Samples via Boron-Doped Diamond Electrode

The voltammetric acyclovir (ACV) trace-level determination procedure has been introduced. This is the first time that a commercially available boron-doped diamond electrode (BDDE) coupled with differential-pulse voltammetry (DPV) has been used for this purpose. The commercially available BDDE is characterized by a short response time, low background current, and very good analytical parameters of ACV determination. Ultimately, DPV measurements using the BDDE in 0.075 mol L<sup>-1</sup> PBS with a pH of 7.2 under optimized conditions achieved the lowest detection limit (LOD = 0.0299 nmol L<sup>-1</sup>) reported in the literature for voltammetric procedures. Moreover, it is highly resistant to the presence of various interfering agents and has been used to analyze pharmaceutical and municipal wastewater samples. The obtained results are consistent with measurements made using chromatographic reference methods.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-09-12
DOI
https://doi.org/10.3390/ma17184480
Citations
2
Primary Topic
Cytomegalovirus and herpesvirus research
Type
article
Field-Weighted Citation Impact
0.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast, Simple, and Sensitive Voltammetric Measurements of Acyclovir in Real Samples via Boron-Doped Diamond Electrode

Ireneusz Sowa, Damian Gorylewski, Magdalena Wójciak, Katarzyna Tyszczuk‐Rotko
2 citations
Materials
Cytomegalovirus and herpesvirus research
0.77
article

Fast, Simple, and Sensitive Voltammetric Measurements of Acyclovir in Real Samples via Boron-Doped Diamond Electrode

Ireneusz Sowa, Damian Gorylewski, Magdalena Wójciak, Katarzyna Tyszczuk‐Rotko
article en
2 citations

Abstract

The voltammetric acyclovir (ACV) trace-level determination procedure has been introduced. This is the first time that a commercially available boron-doped diamond electrode (BDDE) coupled with differential-pulse voltammetry (DPV) has been used for this purpose. The commercially available BDDE is characterized by a short response time, low background current, and very good analytical parameters of ACV determination. Ultimately, DPV measurements using the BDDE in 0.075 mol L<sup>-1</sup> PBS with a pH of 7.2 under optimized conditions achieved the lowest detection limit (LOD = 0.0299 nmol L<sup>-1</sup>) reported in the literature for voltammetric procedures. Moreover, it is highly resistant to the presence of various interfering agents and has been used to analyze pharmaceutical and municipal wastewater samples. The obtained results are consistent with measurements made using chromatographic reference methods.

MaterialsVol. 17(18)
Medical University of Lublin (PL), Maria Curie-Skłodowska University (PL)
Openalex Percentile: Top 25%
Cytomegalovirus and herpesvirus research
0.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fast, Simple, and Sensitive Voltammetric Measurements of Acyclovir in Real Samples via Boron-Doped Diamond Electrode — Ireneusz Sowa, Damian Gorylewski, et al. · Materials (2024) | TGRS Research Map | TGRS