Optical coherence tomography-guided laser osteotomy: toward improvement of ablation efficiency

Abstract This study proposes an additional feature of optical coherence tomography (OCT) as a guidance system for laser surgery, aiming to enhance ablation efficiency during laser osteotomy. A long-range Bessel-like beam OCT system is integrated with an Er:YAG laser. The signal sensitivity of the OCT system is measured under various conditions encountered during laser osteotomy. The results demonstrate that the OCT sensitivity decreases from 87.53 dB to 79.54 dB and 68.93 dB in the presence of debris and water, respectively. These findings highlight the potential application signal sensitivity of OCT as a criterion for detecting the accumulation of water and debris, which could lead to a reduction in ablation efficiency during laser osteotomy using Er:YAG laser.

Authors

Institutions

Publication Details

Journal
Current Directions in Biomedical Engineering
Published
2024-09-12
DOI
https://doi.org/10.1515/cdbme-2024-1054
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical coherence tomography-guided laser osteotomy: toward improvement of ablation efficiency

Ferda Canbaz, Arsham Hamidi, Philippe Claude Cattin
Current Directions in Biomedical Engineering
Intraocular Surgery and Lenses
article

Optical coherence tomography-guided laser osteotomy: toward improvement of ablation efficiency

Ferda Canbaz, Arsham Hamidi, Philippe Claude Cattin
article en

Abstract

Abstract This study proposes an additional feature of optical coherence tomography (OCT) as a guidance system for laser surgery, aiming to enhance ablation efficiency during laser osteotomy. A long-range Bessel-like beam OCT system is integrated with an Er:YAG laser. The signal sensitivity of the OCT system is measured under various conditions encountered during laser osteotomy. The results demonstrate that the OCT sensitivity decreases from 87.53 dB to 79.54 dB and 68.93 dB in the presence of debris and water, respectively. These findings highlight the potential application signal sensitivity of OCT as a criterion for detecting the accumulation of water and debris, which could lead to a reduction in ablation efficiency during laser osteotomy using Er:YAG laser.

Current Directions in Biomedical EngineeringVol. 10(2)
University of Basel (CH)
Clean water and sanitation
Openalex Percentile: Top 74%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.