Validation and efficacy of the Varix Trainer model as a Training device for esophagogastroduodenoscopy

<b>Background and study aims</b> The Varix Trainer model 1 (VTM1) was created for trainees to safely practice basic endoscope manipulation skills. The VTM1 was tested to see if it could distinguish levels of endoscope manipulation skills (construct validity) and whether training with it could improve these skills faster (content validity). <b>Patients and methods</b> We enrolled 23 novice endoscopists, 18 second-year trainees, and 13 expert endoscopists. They were asked to point with the endoscope tip to 20 numbers in the model as quickly as possible using torque, single-hand small/large wheel manipulation (SHSW), and retroflexion techniques. Their mean times (t20) were compared to determine if the model could distinguish different levels of expertise. Subsequently, 14 novices trained for eight short sessions, and the pre-training and post-training t20 were compared. Nine novice endoscopists received no training and were retested after 4 to 6 weeks (controls). <b>Results</b> Experts had faster t20 than second-year trainees, who were faster than novices, for all three techniques ( <i>P</i> < 0.001). After eight sessions, the mean t20 for novices improved from 112 to 66 seconds for torque, 144 to 72 seconds for SHSW, and 108 to 63 seconds for retroflexion, (all <i>P</i> < 0.001). Their t20 were equivalent to second-year trainees. Improvement in t20 was also seen with the control group, but total reduction was less than for the training group. <b>Conclusions</b> The VTM1 distinguished varying levels of expertise for all techniques, suggesting that it is a valid tool for assessing endoscope manipulation skill. A short curriculum improved novices' manipulation skills faster than traditional practice.

Authors

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2024-09-01
DOI
https://doi.org/10.1055/a-2374-8476
Citations
1
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation and efficacy of the Varix Trainer model as a Training device for esophagogastroduodenoscopy

Julajak Limsrivilai, Tanyaporn Chantarojanasiri, Taya Kitiyakara, Chitchai Rattananukrom et al.
1 citations
Endoscopy International Open
Surgical Simulation and Training
0.57
article

Validation and efficacy of the Varix Trainer model as a Training device for esophagogastroduodenoscopy

Julajak Limsrivilai, Tanyaporn Chantarojanasiri, Taya Kitiyakara, Chitchai Rattananukrom, Thanawin Wong, Jaksin Sottisuporn, Uayporn Kaosombatwattana, Kamin Harinwan, Parit Mekaroonkamol, Nonthalee Pausawasdi, Nalerdon Chalermsuksant, Phalat Sathirawich, Rapat Pittayanon, Sarunporn Kamolvisit, Sasivimol Rattanasiri, Akharawit Pulsombat, Onuma Sattayalertyanyong, Patarapong Kamalaporn
article en
1 citations

Abstract

<b>Background and study aims</b> The Varix Trainer model 1 (VTM1) was created for trainees to safely practice basic endoscope manipulation skills. The VTM1 was tested to see if it could distinguish levels of endoscope manipulation skills (construct validity) and whether training with it could improve these skills faster (content validity). <b>Patients and methods</b> We enrolled 23 novice endoscopists, 18 second-year trainees, and 13 expert endoscopists. They were asked to point with the endoscope tip to 20 numbers in the model as quickly as possible using torque, single-hand small/large wheel manipulation (SHSW), and retroflexion techniques. Their mean times (t20) were compared to determine if the model could distinguish different levels of expertise. Subsequently, 14 novices trained for eight short sessions, and the pre-training and post-training t20 were compared. Nine novice endoscopists received no training and were retested after 4 to 6 weeks (controls). <b>Results</b> Experts had faster t20 than second-year trainees, who were faster than novices, for all three techniques ( <i>P</i> < 0.001). After eight sessions, the mean t20 for novices improved from 112 to 66 seconds for torque, 144 to 72 seconds for SHSW, and 108 to 63 seconds for retroflexion, (all <i>P</i> < 0.001). Their t20 were equivalent to second-year trainees. Improvement in t20 was also seen with the control group, but total reduction was less than for the training group. <b>Conclusions</b> The VTM1 distinguished varying levels of expertise for all techniques, suggesting that it is a valid tool for assessing endoscope manipulation skill. A short curriculum improved novices' manipulation skills faster than traditional practice.

Endoscopy International OpenVol. 12(09)
Prince of Songkla University (TH), Siriraj Hospital (TH), Chulalongkorn University (TH), Khon Kaen University (TH), Mahidol University (TH), Navamindradhiraj University (TH), Vajira Hospital (TH), King Chulalongkorn Memorial Hospital (TH), Phramongkutklao Hospital (TH), Songklanagarind Hospital (TH), Rajavithi Hospital (TH), Ramathibodi Hospital (TH), Royal Thai Army, Rangsit University (TH)
Quality Education
Openalex Percentile: Top 30%
Surgical Simulation and Training
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.