Behavior of Post -Tensioned High Strength Concrete Slabs with Opening

Design of slabs using the Post tension system, became now a very popular technique in design specially for large span slabs. the main advantage of using PT (Post-Tensioned) in design, is reducing the amount of used steel reinforcement, used in heavy loaded floors as it reduces the thickness of slab by about 20%, This leads to reduce the loads carried by columns and by turn reducing foundation dimensions; especially in high rise building. Recently, investigating the problem of using this type of slab with different opening dimensions and location are limited to a certain aspects.Frequently, the presence of opening in slab is highly required for passing the different construction services like A.C Lines, electrical cables, pipes of gas & water, etc…. In this paper, the effect of openings in PT slabs has been investigated experimentally. An experimental program consisting of six square flat plate specimens, had been carried out. All specimens were made of high strength concrete with target strength fcu= 80 kN/mm² and had a variable opening ratios.

Authors

Institutions

Publication Details

Journal
Engineering Research Journal
Published
2024-09-01
DOI
https://doi.org/10.21608/erj.2024.377456
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior of Post -Tensioned High Strength Concrete Slabs with Opening

Mohamed H. Mathana, Hamed S. Askar, Mohamed E. El-Zoughiby, Mohamed A. Hemid
Engineering Research Journal
Structural Behavior of Reinforced Concrete
article

Behavior of Post -Tensioned High Strength Concrete Slabs with Opening

Mohamed H. Mathana, Hamed S. Askar, Mohamed E. El-Zoughiby, Mohamed A. Hemid
article en

Abstract

Design of slabs using the Post tension system, became now a very popular technique in design specially for large span slabs. the main advantage of using PT (Post-Tensioned) in design, is reducing the amount of used steel reinforcement, used in heavy loaded floors as it reduces the thickness of slab by about 20%, This leads to reduce the loads carried by columns and by turn reducing foundation dimensions; especially in high rise building. Recently, investigating the problem of using this type of slab with different opening dimensions and location are limited to a certain aspects.Frequently, the presence of opening in slab is highly required for passing the different construction services like A.C Lines, electrical cables, pipes of gas & water, etc…. In this paper, the effect of openings in PT slabs has been investigated experimentally. An experimental program consisting of six square flat plate specimens, had been carried out. All specimens were made of high strength concrete with target strength fcu= 80 kN/mm² and had a variable opening ratios.

Engineering Research JournalVol. 183(3)
Mansoura University (EG)
Sustainable cities and communities
Openalex Percentile: Top 84%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.