Analysis of UFR Criteria Based on System Analysis According to Expansion of Renewable Energy

As the penetration of Variable Renewable Energy (VRE) increases, the power system may face risks of frequency decline due to the degradation of system inertia and an increase in the Rate of Change of Frequency (RoCoF). The negative impact on frequency stability highlights the importance of establishing Under Frequency Relay (UFR) as well as defining procedures and criteria for frequency decline protection. For UFR analysis, real performance data is extracted based on the current electrical facilities and loads connected to the system. By reflecting this extracted data, system constants are calculated, and through these constants, frequency computations over time are conducted to establish optimal operating strategies for UFR. In other words, current methods of establishing UFR standards are based on real data. However, this paper analyzes UFR standards in operation using the Power Simulation Simulator for Engineering (PSS/E), a large-scale power system analysis program, establishes an optimal UFR operation plan for the system, and targets future systems that are planned but not yet connected

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-08-31
DOI
https://doi.org/10.5370/kiee.2024.73.8.1280
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of UFR Criteria Based on System Analysis According to Expansion of Renewable Energy

Jae-Hyun Min, Yeong-Beom Kim, Yun-Ho Nam, Yoon-Sung Cho
The Transactions of The Korean Institute of Electrical Engineers
Integrated Energy Systems Optimization
article

Analysis of UFR Criteria Based on System Analysis According to Expansion of Renewable Energy

Jae-Hyun Min, Yeong-Beom Kim, Yun-Ho Nam, Yoon-Sung Cho
article en

Abstract

As the penetration of Variable Renewable Energy (VRE) increases, the power system may face risks of frequency decline due to the degradation of system inertia and an increase in the Rate of Change of Frequency (RoCoF). The negative impact on frequency stability highlights the importance of establishing Under Frequency Relay (UFR) as well as defining procedures and criteria for frequency decline protection. For UFR analysis, real performance data is extracted based on the current electrical facilities and loads connected to the system. By reflecting this extracted data, system constants are calculated, and through these constants, frequency computations over time are conducted to establish optimal operating strategies for UFR. In other words, current methods of establishing UFR standards are based on real data. However, this paper analyzes UFR standards in operation using the Power Simulation Simulator for Engineering (PSS/E), a large-scale power system analysis program, establishes an optimal UFR operation plan for the system, and targets future systems that are planned but not yet connected

The Transactions of The Korean Institute of Electrical EngineersVol. 73(8)
Affordable and clean energy
Openalex Percentile: Top 87%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of UFR Criteria Based on System Analysis According to Expansion of Renewable Energy — Jae-Hyun Min, Yeong-Beom Kim, et al. · The Transactions of The Korean Institute of Electrical Engineers (2024) | TGRS Research Map | TGRS