A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dVcm/dt ∼ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the Bp coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-09-01
DOI
https://doi.org/10.1063/5.0219341
Citations
2
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
1.32

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A magnetic diagnostic suite for the Pegasus-III experiment

G. R. Winz, Justin D. Weberski, M. W. Aslin, S. J. Diem et al.
2 citations
Review of Scientific Instruments
Magnetic confinement fusion research
1.32
article

A magnetic diagnostic suite for the Pegasus-III experiment

G. R. Winz, Justin D. Weberski, M. W. Aslin, S. J. Diem, J. A. Goetz, A.C. Sontag, Rachel Sassella, M. D. Nornberg, M.W. Bongard, C. Rodriguez Sanchez, J.A. Reusch, Anupama S. Rajendra, S. Redd
article en
2 citations

Abstract

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dVcm/dt ∼ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the Bp coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

Review of Scientific InstrumentsVol. 95(9)
University of Wisconsin–Madison (US)
U.S. Department of Energy, Office of Science, Fusion Energy Sciences
Affordable and clean energy
Openalex Percentile: Top 11%
Magnetic confinement fusion research
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.