ANALYSIS OF SAIDI AND SAIFI STABILITY IN THE DISTRIBUTION SYSTEM AT PT. PLN (PERSERO) ULP FAKFAK

The increasing need for electrical energy requires the reliability of good electrical power distribution. Intentional or unintentional blackouts caused by electrical disturbances will certainly be detrimental to both PLN parties themselves. Several parameters that can be used as a reference in determining the reliability of a distribution system are by calculating SAIFI (System Average Interruption Frequency Index) which is an index calculation of the average number of disturbances during each month and SAIDI (System Average Interruption Duration Index) which is an index of the average duration of disruption to the system for one month. Analysis of the condition of the level of reliability of the distribution system at PT. PLN (Persero) ULP Fakfak aims to determine the monthly reliability of SAIDI and SAIFI in the distribution system at PT. PLN (Persero) ULP Fakfak whether it still meets the SAIDI and SAIFI target values at PT. PLN (Persero) ULP Fakfak.. The method used is a qualitative-descriptive approach. The results obtained are the SAIDI and SAIFI PT eligibility standard values. PLN (Persero) ULP Fakfak in the month standard used for SAIDI is the limit of 79.01 hours / plg - 308.00 hours / plg and the SAIFI standard is 0.56 times / plg - 1.86 times / plg. From the results of SAIDI calculations for 5 months from February - June, it can be seen that in May the SAIDI value was much better than the target set by PLN, namely 17.24 hours / plg. Meanwhile, SAIFI according to the calculation results was 0.16 times / home from 1.38 times / home in May set by PT. PLN (Persero) ULP Fakfak. Keywords: SAIDI, SAIFI, Reliability, Distribution Systems.

Authors

Institutions

Publication Details

Journal
Jurnal Media Elektrik
Published
2024-09-08
DOI
https://doi.org/10.59562/metrik.v21i3.3501
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF SAIDI AND SAIFI STABILITY IN THE DISTRIBUTION SYSTEM AT PT. PLN (PERSERO) ULP FAKFAK

Rusliadi Rusliadi, Naomi Lembang, Yulianto La Elo, Nurul Husnah et al.
Jurnal Media Elektrik
Engineering and Technology Innovations
article

ANALYSIS OF SAIDI AND SAIFI STABILITY IN THE DISTRIBUTION SYSTEM AT PT. PLN (PERSERO) ULP FAKFAK

Rusliadi Rusliadi, Naomi Lembang, Yulianto La Elo, Nurul Husnah, Yurika Nantan Nantan
article en

Abstract

The increasing need for electrical energy requires the reliability of good electrical power distribution. Intentional or unintentional blackouts caused by electrical disturbances will certainly be detrimental to both PLN parties themselves. Several parameters that can be used as a reference in determining the reliability of a distribution system are by calculating SAIFI (System Average Interruption Frequency Index) which is an index calculation of the average number of disturbances during each month and SAIDI (System Average Interruption Duration Index) which is an index of the average duration of disruption to the system for one month. Analysis of the condition of the level of reliability of the distribution system at PT. PLN (Persero) ULP Fakfak aims to determine the monthly reliability of SAIDI and SAIFI in the distribution system at PT. PLN (Persero) ULP Fakfak whether it still meets the SAIDI and SAIFI target values at PT. PLN (Persero) ULP Fakfak.. The method used is a qualitative-descriptive approach. The results obtained are the SAIDI and SAIFI PT eligibility standard values. PLN (Persero) ULP Fakfak in the month standard used for SAIDI is the limit of 79.01 hours / plg - 308.00 hours / plg and the SAIFI standard is 0.56 times / plg - 1.86 times / plg. From the results of SAIDI calculations for 5 months from February - June, it can be seen that in May the SAIDI value was much better than the target set by PLN, namely 17.24 hours / plg. Meanwhile, SAIFI according to the calculation results was 0.16 times / home from 1.38 times / home in May set by PT. PLN (Persero) ULP Fakfak. Keywords: SAIDI, SAIFI, Reliability, Distribution Systems.

Jurnal Media ElektrikVol. 21(3)
Politeknik Kesehatan Kemenkes Semarang (ID)
Openalex Percentile: Top 87%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALYSIS OF SAIDI AND SAIFI STABILITY IN THE DISTRIBUTION SYSTEM AT PT. PLN (PERSERO) ULP FAKFAK — Rusliadi Rusliadi, Naomi Lembang, et al. · Jurnal Media Elektrik (2024) | TGRS Research Map | TGRS