Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

Abstract Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti‐interference, and adaptability, and can provide basic information for harmonic localisation and traceability.

Authors

Institutions

Publication Details

Journal
IET Electric Power Applications
Published
2024-09-09
DOI
https://doi.org/10.1049/elp2.12481
Citations
6
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
1.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

Xiaoxian Zhu, Dexu Zou, Haozhou Wang, Qingjun Peng et al.
6 citations
IET Electric Power Applications
Non-Destructive Testing Techniques
1.28
article

Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

Xiaoxian Zhu, Dexu Zou, Haozhou Wang, Qingjun Peng, Shan Wang, Fangrong Zhou, Desheng Chu
article en
6 citations

Abstract

Abstract Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti‐interference, and adaptability, and can provide basic information for harmonic localisation and traceability.

IET Electric Power ApplicationsVol. 18(10)
China Southern Power Grid (China) (CN), Beihang University (CN)
Electric Power Research Institute, Yunnan Power Grid Company
Openalex Percentile: Top 23%
Non-Destructive Testing Techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.