Process deviation detection method for dry‐type air‐core reactor based on power factor frequency characteristics

Abstract To address the problem that the process deviation of dry‐type air‐core reactors cannot be effectively detected, electrical parameters of reactor are numerically analysed at different frequencies. A new method of process deviation detection by the power factor frequency characteristic is proposed. Considering on‐site power frequency interference, a harmonic analysis method is proposed, which is based on the integer multiple of the power frequency cycle, to calculate the power factor. The results show that the resistance loss remains relatively constant at power frequency and gradually increases at higher frequencies with the number of deviation turns increases. The eddy current loss remains basically unchanged at different turn deviations and frequencies. The change laws of resistance loss and the resistance loss power factor are the same. In a double logarithmic coordinate system, resistance loss power factor changes from linear to non‐linear. The non‐linearity degree can be used to detect the process deviation. The test results are consistent with the theory, and the correctness of the detection method is verified.

Authors

Institutions

Publication Details

Journal
IET Science Measurement & Technology
Published
2024-09-10
DOI
https://doi.org/10.1049/smt2.12222
Citations
3
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Process deviation detection method for dry‐type air‐core reactor based on power factor frequency characteristics

Zihe Meng, Chunming Zhao, Yonghong Wang, Yu Zhuang et al.
3 citations
IET Science Measurement & Technology
Fault Detection and Control Systems
0.98
article

Process deviation detection method for dry‐type air‐core reactor based on power factor frequency characteristics

Zihe Meng, Chunming Zhao, Yonghong Wang, Yu Zhuang, Xingyu Ge
article en
3 citations

Abstract

Abstract To address the problem that the process deviation of dry‐type air‐core reactors cannot be effectively detected, electrical parameters of reactor are numerically analysed at different frequencies. A new method of process deviation detection by the power factor frequency characteristic is proposed. Considering on‐site power frequency interference, a harmonic analysis method is proposed, which is based on the integer multiple of the power frequency cycle, to calculate the power factor. The results show that the resistance loss remains relatively constant at power frequency and gradually increases at higher frequencies with the number of deviation turns increases. The eddy current loss remains basically unchanged at different turn deviations and frequencies. The change laws of resistance loss and the resistance loss power factor are the same. In a double logarithmic coordinate system, resistance loss power factor changes from linear to non‐linear. The non‐linearity degree can be used to detect the process deviation. The test results are consistent with the theory, and the correctness of the detection method is verified.

IET Science Measurement & TechnologyVol. 18(9)
Harbin University of Science and Technology (CN), Harbin Institute of Technology (CN), Jilin Electric Power Research Institute (China) (CN)
Openalex Percentile: Top 24%
Fault Detection and Control Systems
0.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.